Installation guide
Advisor Master Programming Guide 37
Part set external siren
NO-Part Set External Siren
*-Change 0-Skip
Yes: A Part Set alarm will activate the External siren.
No: A Part Set alarm will not activate the External siren
Note: if the zone causing the alarm is assigned to a multiple areas and any of
these areas has the Part Set External Siren enabled, the external siren will
sound.
Part set access to E/E
YES-Part Set Access to E/E
*-Change 0-Skip
If set to Yes, the operation of any access zone in the Part Set area is change to
operate as an entry exit zone. The purpose of this is to allow access to the
disarming keypad when it is in the view of an access detection zone (PIR).
Example: A residential property with an external entry exit door leading to a hall
in which the arming/disarming keypad is fitted, and is in the view of an access
PIR detector. For Full Set disarming the normal entry will be; to activate the entry
(exit) zone first starting the entry time and inhibiting the access zone; so when
accessing the hall area to disarm, the access zone does not activate the alarm.
This operation is not normally possible when the user stays in the premises and
is Part Set disarming the area, as the user will access the keypad directly without
activating the entry time. This will activate the access detector without starting
the entry time and will cause an alarm condition. To avoid this situation when
Part Set armed, this menu allows all access zones in the area to change there
operation to entry exit allowing the user to access the keypad to disarm a Part
Set arming, and only starting the entry time when coming into view of the access
zone.
Yes: An access zone (type 4 or 14) operation is change to an entry/exit zone (3
or 13) operation when Part Set armed.
No: Normal operation for the entry exit zone type programmed.
Enable part set reporting
NO-Enable Part Set Reporting
*-Change 0-Skip
Yes: Normal programmed reporting.
No: Intruder armed alarm reporting is disabled. The A alarm event flag, B alarm
event flag and the Disarm flag are also disabled. 24 hour zone types, system
alarms and tamper alarms will still report.