Installation guide

38 Advisor Master Programming Guide
Disable part set B-alarms
NO-Disable Part Set B-Alarms
*-Change 0-Skip
Note: This menu is only applicable if Part Set reporting is set to Yes.
Yes: Alarm confirmation (BV) reporting is disabled when Part Set armed. First
alarm report type (BA) is reported for all intruder alarms The B confirmed alarm
event flag and the ‘Engineer reset on B alarm’ are also disabled.
No: Normal Alarm confirmed reporting for Part Set.
Chime on RAS
Chime on RAS: 0
0=NO RAS
Select a RAS address number to sound its buzzer when an area’s chime event
occurs.
0: no RAS selected, RAS buzzers will not be activated.
1 to 16: RAS 1 to 16. The selected RAS address will activate its buzzer for
the duration of the chime event.
Only one RAS address may be selected in this menu. If all RAS buzzers are to
activate, allocate the Chime event flag number to System Flags Keypad buzzers.
For more information see System Options > Enable chimeon page 87.