Installation guide
Advisor Master Programming Guide 41
Table 5: Programming the arming stations
Programmable function
Arming stations
ATS1100
ATS1110
ATS1111
ATS1105
ATS1115
ATS1116
ATS1151
ATS1155
ATS1156
ATS1197
ATS1170
LCD arming station
Y
Y
N
N
Toggle Area status
N
N
O [1]
O
Enter key opens door only
O
O
O
N
Door event flag on alarm codes
O
O
O
N
Display shunted zone on LCD
O
O
N
N
Arm/disarm using one key
O [2]
O [2]
N
N
Cards auto disarm
N
O
N
O
Card always arms/disarms
N
O
N
O
Reset from RAS without code
O
O
O
N
AG restriction disarm only
O
O
O
O
Legend:
Y Must be set to Yes
N Must be set to No
O Optional
[1] The "Toggle Area status" option is NOT recommended
[2] CAUTION! If a LCD arming station is used as master; and "Arm/disarm using one key" is set
to Yes; the system must be programmed so that areas 9 to 16 can never be armed
Toggle Area status
NO-Code ENTER Toggles Area Status
*-Change 0-Skip
Toggle area status provides users with an option to have arm control on keypads
combined with readers.
Yes: The On and Off keys have lost their function. For arm control one needs to
enter the user code followed by On, Off or Enter. If a list of areas appears,
pressing the area number and Enter toggles the status of the area. If no list is
available, the status of the area(s) is toggled immediately.
No: Normal alarm control.
Notes
• Do not use this option if “Enter key opens door only” on page 42 is set to Yes.
• Using this option is not recommended.
See Table 5 on page 41 for further information on options available to arming
stations.
See Table 6 on page 42 for information on using card readers for alarm control.