Installation guide

42 Advisor Master Programming Guide
Table 6: Using card readers for alarm control
Function
Programming options
Toggle
area
Card
auto
Card
always
Notes
Card, OFF disarms
Card, ON arms
No
No
No
ATS1105, ATS1115, ATS1116, ATS1151,
ATS1155, ATS1156, ATS1197 only
Card disarms
Card arms
Yes
No
Yes
Enter key opens door only
YES-ENTER Key Opens Door Only
*-Change 0-Skip
Yes: When using LCD arming stations, using the On and Off key for alarm
control results in a clearer user interface. It also provides an option to use the
Enter key for opening a door with a keypad.
No: The Enter key unlocks the door, but also provides alarm control and resets
alarms.
See Table 5 on page 41 for further information on options available to arming
stations.
Note: Set this option to Yes for the best user interface on LCD arming stations.
Door event flag on alarm codes
NO-Door Event Flag On Alarm Codes
*-Change 0-Skip
Yes: If user codes with alarm control and door groups perform alarm control, the
door will unlock.
No: User codes with alarm control will not unlock doors.
See Table 5 on page 41 for further information on options available to arming
stations.
Note: The user needs to have alarm control and a door group.
Display shunted zone on LCD
NO-Display Shunting on LCD
*-Change 0-Skip
Yes: When a zone is shunted, the text ‘Zone shunted,’ will appear on the display.
No: Nothing is shown when a zone is shunted.
See Table 5 on page 41 for further information on options available to arming
stations.