Installation guide
52 Advisor Master Programming Guide
from a list of words that you have programmed yourself (see “10-Program text”
on page 102).
The display shows the current alarm group name, preceded by its reference
number).
Areas assigned
1,2,3,5,7,8,9,
Area:
Assign the areas to be controlled by the alarm group. An alarm group can only
control the functions of areas that are assigned to it.
User alarm group
No-Can this GRP Be Assigned To Users
*-Change 0-Skip:
Define if the alarm group can be assigned to users, or only to zones and RAS’s.
Yes: This alarm group can be assigned to users. The group is displayed in the
list of alarm groups when creating a user in user menu 14-Users. This option is
not set for alternate user alarm groups.
No: This alarm group is for a zone, door or RAS.
Press 0 to go to the user menu items available.
Note: An alarm group is only displayed in User Codes when the user who is
creating a new user has at least the same options (includes check of alternate
alarm group). A user cannot create a code for another user who has higher
security clearance.
Alarm system control
YES-Alarm System Control
*-Change 0-Skip:
This record lets you assign alarm system control functions to a user, door or
RAS. Only when alarm system control is enabled can users arm or disarm areas
in the alarm group.
Yes: Alarm system control is enabled. Users, doors or RAS’s can arm or disarm
the areas in the alarm group.
No: No alarm system control available. Access control functions and any user
menu options specified are still valid.
Press 0 to go to the user menu items available.
Note: You must set this record to Yes if any of the alarm group restrictions in the
Alarm Group are set to Yes.