Installation guide

Advisor Master Programming Guide 59
Each user menu is displayed and must be set to Yes for it to be available to the
alarm group. The user menus available for selection are:
Table 8: User menu options available
1.
Panel status
15.
Time & date
2.
Active zones
16.
Isolate/de-isolate RAS/DGP
3.
Zones in alarm
17.
Authorization Service In
4.
Inhibited zones
18.
Reset cameras
5.
History
19.
Installer programming
6.
Test report
20.
Door and floor groups
7.
Service menu
21.
Holidays
8.
Film counters
22.
Open door
9.
List zone names
23.
Unlock, lock, disable and enable
10.
Inhibit zone
24.
Print history
11.
Uninhibit zone
25.
TML menu entry
12.
Walk test
26.
Chime options
13.
Start auto disarm test
27.
HSR management
14.
Program users
See the Advisor Master Manager’s Manual for further information on each option.
Press 0 to go to timezone.
Timezone
Alm-Grp 14 Timezone 4
Timezone:
Determines the timezone that applies to this alarm group. The alarm group is
only available if the timezone is valid.
For information on operating timezones, see 13-Timezones (page 111), and
22-Timezone to follow output (page 134).
Alternate alarm group
Grp 14 Alt-Grp 12 - Night Shift
Alm-Grp:
You can program each alarm group to have an alternate alarm group. The
alternate alarm group is used whenever the original alarm group is disabled due
to an invalid timezone. The alternate alarm group can have other areas or menus
as the original alarm group.
Example: During normal working hours, users can arm and disarm from a list.
After hours, only arm/alarm reset is allowed without presenting a list of areas.