• The alternate alarm group can also be programmed with an alternate alarm
group and so on - up to three alarm groups (the original plus two alternates).
If a function is denied by the timezone of one alarm group, the next will be
checked, etc.
• When alternate alarm groups are active and these have alarm group
restrictions, the alternate alarm group restrictions apply. See also 15-Alarm
group restrictions on page 115.
User level
Alm-Grp 31 User Level 0
A read-only option User level allows you to discriminate between the user access
levels. The following values are available:
• Disabled (standard ATS panel user - has no overriding capability)
• Level 2 user
• Level 3 user
Items that prevent setting but may be overridden by the Grade 2 level 2 user:
• Detector masked
• Detector fault
• AC mains fail (this includes any DGP)
• Battery low or missing (this includes any DGP)
• All signalling paths in fault
• All warning devices and all signalling paths in fault
Items that prevent setting but may be overridden by the Grade 2 level 3 user:
• Detector masked
• Detector fault
• AC mains fail (this includes any DGP)
• Battery low or missing (this includes any DGP)
• All signalling paths in fault
• All warning devices and all signalling paths in fault
Items that prevent setting but may be overridden by the Grade 3 level 2 user:
• Detector masked
• Detector fault
• AC mains fail (this includes any DGP)
• Battery low or missing (this includes any DGP)
Items that prevent setting but may be overridden by the Grade 3 level 3 user:
• Detector masked
• Detector fault
• AC mains fail (this includes any DGP)
• Battery low or missing (this includes any DGP)
• All signalling paths in fault
• All warning devices and all signalling paths in fault