62 Advisor Master Programming Guide
6-Timers
Program all system wide timers in this section.
Notes
Timers are accurate on ±1 of the value entered. So a timer set for 20
seconds, will end somewhere between 19 and 21 seconds. Consequently,
avoid using values of 1 second or 1 minute.
If a timer is set to 0, that timer will not be used.
Timer settings
AG restriction 1 disarmed time
Alm/Grp Restr.1 Disarmed is (Min). 0
Time:
You need to program the individual times (from 0 to 255 minutes) for each alarm
group restriction 1 to 7 for the time it is disarmed. The alarm group restriction has
to be programmed for timed disarm and be assigned to an alarm group.
Notes
If set to 0, the area(s) will not re-arm automatically. See 15-Alarm group
restrictionson page 115 for more information.
The alarm group restriction time will be over-ridden by the Area disarmed
timeon page 33 (if programmed) in the Area database.
AG restriction 2 disarmed time
See AG restriction 1 disarmed timeabove.
AG restriction 3 disarmed time
See “AG restriction 1 disarmed timeabove.
AG restriction 4 disarmed time
See “AG restriction 1 disarmed timeabove.
AG restriction 5 disarmed time
See “AG restriction 1 disarmed timeabove.
AG restriction 6 disarmed time
See “AG restriction 1 disarmed timeabove.