Installation guide
Advisor Master Programming Guide 63
AG restriction 7 disarmed time
Alm/Grp Restr.7 Disarmed is (Min). 0
Time:
After the disarmed time has expired, not only the area(s) are armed, but also an
emergency alarm will be sent to the central station.
See “AG restriction 1 disarmed time” on page 62 and “15-Alarm group
restrictions” on page 115.
AG restriction 8 disarmed time
Alm/Grp Restr.8 ** NOT USED **
Time:
The disarmed time for alarm group restriction 8 does not have any significance,
because the system ignores any values entered here. Alarm group restriction 8,
when used counts every user disarming and arming again. The timer is internally
set to 0.
See “15-Alarm group restrictions” on page 115.
Disarm test time
Disarm Test Set To (Min) 15
Time:
Determines the test time available to perform the disarm test (0 to 255 minutes).
See “7-System options” on page 70, and “1-Zone database” on page 7 for more
information on testing zones.
Arm test time
Arm Test Set To (Min) 15
Time:
Determines the test time available to perform the arm test (0 to 255 minutes).
Warning time
Warning Time Is Set To (Min) 15
Time:
When alarm group restrictions are used and areas are programmed for timed
disarm, a warning will sound (if a warning time is programmed) indicating the
areas are about to arm. The duration this warning will sound is programmed in
this menu (0 to 255 minutes)
When a warning time is set, an audible alert is provided for the warning period
preceding the expiry. It MUST always be shorter than the shortest alarm group
restriction time.