Advisor Master Programming Guide 65
Individual zone test time
Individual Testmode Time (Min). 5
Time:
Enter the maximum time (0 to 255 minutes) to perform a test on an individual
zone, using user menu Test zone.
Note: See the manager guide, user menu Test zone for more information.
Doors unlock time
Door(s) Unlock Time (Sec). 5
Time:
The time doors will unlock (using the door event flag). This time value is common
for all door event flags from RAS’s connected to the ATS system, i.e. doors 1 to
16. Doors 17 to 64 are connected to ATS125x/1260 4-door/lift DGP’s that are
individually programmed in the DGP.
Note: See also 3-RAS databaseon page 39.
Testing event flag time
Testing Event Flag Time (Sec). 15
Time:
Specify the time the testing event flag is triggered to activate devices in order to
perform an arm test. The event flag will only be triggered for half the programmed
time. The remaining time is used to allow the device to switch back to normal
state.
The event flag used is preset to 16.
More on event flags in Event Flagson page 177.
External siren set to
External Siren Set to (Min)
Time:
This option specifies the amount of time (0 to 255 minutes) that the on-board
external siren drivers activate. The maximum time is 255 minutes.
See 1-Zone databaseon page 7 and 2-Area databaseon page 28 for more
information.
Internal siren set to
Internal Siren Set to (Min)
Time:
This option specifies the amount of time (0 to 255 minutes) that the on-board
internal siren drivers activate. The maximum time is 255 minutes.
See “1-Zone databaseon page 7 and “2-Area databaseon page 28 for more
information.