Abort time (sec)
Abort Time (sec). 30
Time:
An additional system “Abort Timer” for entry fault reporting is implemented to
create an additional delay of 30 seconds (programmable from 0 to 255) after the
entry time has been expired before the entry fault is reported.
RAS lockout time
RAS Lockout Time (sec). 90
Time:
Allows you to set the time, for which the RAS becomes locked after a code
tamper. The allowed range is 1 to 255 seconds.
See also “Timed lockout by wrong codeson page 44.
Chime time is set to
Chime Time Is Set To (sec). 90
Time:
The active time for the chime event flag. If applicable, this time is also applied to
the RAS chime buzzer duration. For more information see System Options >
Enable chimeon page 87.
Computer access time
Computer Access Time (min). 60
Time:
This field has an effect only when Authorize computer connection option on
page 144 is set. The option specifies how long the special authorization for
computer connection is valid. The default value is 60 min meaning that after the
user authorizes the computer connection, the authorization is valid for
60 minutes.
Access time for PIN of the day
Access Time For PIN Of The Day (Min):
Time:
Enter the time in minutes, for which the provided response code is valid and the
new code is not required. See “PIN of the day optionon page 89 for more
information.