Installation guide
Advisor Master Programming Guide 71
Film out level
Film Out Is Set To 1100
Film Level:
The film level number programmed is the film frame count. When this frame
count is reached, an out of film is reported to the central station. This option is
related to the camera count zone types 23 to 26 and 36 to 39.
Note: Relates to zone types 23 to 6 and 36 to 39 (camera count). See “1-Zone
database” on page 7.
Test mode
1, Enable Auto Test
Option:
The test mode determines if or when an arm or disarm test has to be performed.
There are four options available. An option is programmed using its reference
number.
• 0-No Test: No automatic tests. A disarm test can be performed using User
menu 13, Start auto disarm test.
• 1-Enable Auto Test: The disarm or arm test starts automatically when the
system is disarmed or armed.
• 2-Manual Disarm Test/Auto Arm Test: The arm test starts automatically when
the system is armed. The disarm test can only be done using User menu 13,
Start auto disarm test.
• 3-Auto Disarm Test Only: The disarm test starts automatically when the
system is disarmed. No arm test is available.
Notes
• For the "Auto disarm test" to operate, the area(s) containing the zones to test
have to be programmed as vaults. See “18-Vaults” on page 126.
• This record does not affect manual testing of any individual zone (User
menu 12). See “54-Test zone” on page 172.
No. of output controllers
Number Of Output Controllers: 2
How Many:
Enter the number of output controllers that are fitted to the main control panel
(J14, see Advisor Master Installation Guide). An output controller has 8 outputs
available.
Valid values:
• 0: No output controller or a 4-way relay (ATS1810).
• 1 to 32: Indicates the number of output controllers (ATS1811). The 16-way
open collector card (ATS1820) and ATS1821 open collector card take up 2
controllers.