Installation guide
72 Advisor Master Programming Guide
Do not enter values here for output controllers fitted to DGP’s.
Zone event text
Zone Text: 0103, Gate
Text No:
When zone types 57 and 58 are active, this zone event text will be displayed on
LCD keypads. The text is taken from the text word library and is programmed as
a reference number. A free programmable text can be programmed using “10-
Program text” on page 102.
The zone event text only appears when the zones are active, for example
“Freezer open”.
See also “1-Zone database” on page 7 and “10-Program text” on page 102.
Alarm code prefix
No Alarm Code Prefix
No Digits:
The alarm code prefix enables user codes to be used for both access control and
alarm control. The prefix indicated the number of digits that have to be entered to
have alarm control. If those digits are not entered, only access control can be
performed.
For example: If the alarm code prefix is two digits and a users PIN is 123456,
then you would enter 123456 for alarm control or 3456 for access control. A
value between one to four digits can be entered.
Note: The minimum PIN length entered has to be 4 digits. The total length of a
users PIN is 4 + alarm code prefix.
LCD rotation delay
LCD Rotation Delay Is 0
Time:
The time before text on the LCD display starts rotating can be altered. The
default value 0, which is equal to 8.
Any value from 9 to 15 increases the time before text rotation starts.
Any value from 1 to 7 decreases the time before text rotation starts.
Note: This option can only be programmed for LCD arming stations, like
ATS1100 or ATS111x.
LCD rotation speed
Rotation Speed Is 0
Time:
Not only the time before text rotation starts can be altered, but also the speed
with which the text rotates. The faster the speed, the harder to read. But when