Advisor Master Programming Guide 73
the speed is too slow, long texts might take too long to show. The default value 0,
which is equal to 8.
Any value from 9 to 15 decreases the text rotation speed.
Any value from 1 to 7 increases the text rotation speed.
Note: This option can only be programmed for LCD arming stations, like
ATS1100 or ATS111x.
Dual zone
NO-Dual zone
*-Change 0-Skip
Determines if dual zone is used. For dual zone to operate, every zone needs
additional end-of-line resistors. This enables the panel to distinguish a few zone
states.
Yes: Dual zone used. All possible states are monitored. See Advisor Master
Installation Guide for more information on zone states.
No: No dual zone; 4.7 kΩ resistance is a normal state; every other resistance is
an alarm.
Press 0 to skip further options and leave system options.
Note: End of line resistors have to be connected to the zone. See Advisor Master
Installation Guide.
Auto uninhibit on disarm
NO-Auto Uninhibit When Area Disarmed
*-Change 0-Skip
Determine if zones are automatically uninhibited if the area is disarmed.
However, this option is only valid if the alarm group allows automatic uninhibit.
Yes: Zones in normal state and inhibited are uninhibited when any of the areas
assigned to the zone are disarmed. This is done to ensure that inhibited zones
are not ignored or overlooked.
No: Zones in normal state and inhibited are not uninhibited when any of the
areas assigned to the zone are disarmed.
Press 0 to skip further options and leave system options.
See also “5-Alarm groups” on page 50.
Display one zone at a time
NO-Display One Zone at a Time
*-Change 0-Skip
This record controls the way zone names and numbers are displayed on the LCD
during user functions.