Installation guide
Advisor Master Programming Guide 75
Note: Remember to program the users alarm group with “Reset system alarms”
set to Yes. See “5-Alarm groups” on page 50.
Siren testing
NO-Test Siren
*-Change 0-Skip
Enable a siren test when the arm test is started.
Yes: The sirens are tested for three seconds when the arm test is started.
No: Sirens are not tested when the arm test is started.
Press 0 to skip further options and leave system options.
See “Test mode” in “7-System options” on page71.
Disable "0, ENTER" for camera reset
NO-Disable 0 ENTER For Camera Reset
*-Change 0-Skip
Defines the procedure to stop cameras from operating. See the Manager Manual
for more information.
Yes: 0, Enter can not be used to stop cameras operating. The cameras continue
to operate until someone who is authorised to control cameras, resets them.
No: 0, Enter stops the cameras operating (after pressing Enter, Enter for the
"Quick alarm log".
Press 0 to skip further options and leave system options.
See also Advisor Master Manager Manual regarding alarms, camera’s and alarm
logs.
Disable insert of AG restriction
NO-Disable Insert Of Alm/Grp Restr.
*-Change 0-Skip
Disables the option to treat areas as vaults. By disabling this option, the non-
vault areas will not be automatically armed.
Yes: Disables the special procedure for automatically timing on non-vault areas
when arming vaults.
No: Enables the special procedure for automatically timing on non-vault areas
when arming vaults, provided all the applicable values are programmed.
Press 0 to skip further options and leave system options.
See “18-Vaults” on page 126.