Advisor Master Programming Guide 77
Yes: Details of the first alarm are displayed instantly on the LCD arming station.
Details of other alarms can be viewed on the LCD arming station by pressing the
Enter key twice.
No: Details of all alarms can be viewed on the LCD arming station by pressing
the Enter key twice.
Press 0 to skip further options and leave system options.
Sirens only after FTC
NO-Sirens Only After Report Fail (FTC)
*-Change 0-Skip
When set to Yes, Siren event flags are only activated on alarms if the ATS
control panel has failed to report to the central station. Fail To Report (FTC) is
registered at the end of the fourth dial attempt. The siren activates for the normal
siren cut-off time programmed.
Yes: Sirens will only activate on alarms when a FTC has occurred.
No: Sirens will operate on alarms.
Press 0 to skip further options and leave system options.
Financial options
NO-Financial Options
*-Change 0-Skip
Activates three special options (generally applicable to financial institution
installations):
Film counters are enabled during the Disarm test mode.
Alarm group restriction 2 or Alarm group restriction 6 disable delayed
Disarmed Alarm zones.
Minimum PIN length is set to 5 digits.
Yes: Financial options enabled
No: Normal operation.
Press 0 to skip further options and leave system options.
Display user flags
NO-Display User Flags
*-Change 0-Skip
Enable the special user flags to be displayed when programming users. The
special user flags are Two Card function, Guard, Visitor, Trace User, Card only,
Privileged and Extended Access.
Yes: The special user flags are displayed in sequence after the "Floor group"
display when programming users.
No: The special user flags are not displayed.