Engineer reset for system tampers
NO-Engineer Reset for System Tamper
*-Change 0-Skip
If an engineer reset is required on system tamper alarms, set this option to Yes.
A user can not arm any area until an engineer reset has been performed.
Yes: Engineer reset required on system tampers.
No: No engineer reset required.
Press 0 to skip further options and leave system options.
Ignore battery fault when arming
NO-Ignore Battery Fault when arming
*-Change 0-Skip
Enables to arm the system without any battery.
User can do engineering reset
NO-User can do Eng. Reset
*-Change 0-Skip
Set this option to Yes if an engineer reset is required. An engineer reset can then
be done by the user entering installer reset code calculated from the 4-digit code
in combination with the ATS system code.
Note: This option by default does not allow users to perform an engineering
reset, except the Installer via Key-switch – Input type 65, Titan or Installer
Menu 19/51.
Engineer entry protect
NO-Engineer Entry Protect
*-Change 0-Skip
This option protects against unauthorised entry by an installer. If set to Yes, you
can only enter menu (19) (Installer programming) by opening the box tamper
within 120 seconds. “Open box tamper” will be displayed. During these
120 seconds or within the installer menus, the box tamper alarm is disabled.
When the installer menu is exited, the installer has 120 seconds to close the box
tamper. If not, the tamper alarm will be activated. The default is set to No.
Send arming after exit
YES-Send Arming After Exit
*-Change 0-Skip
If set to Yes, when armed, an area will defer the reporting of arming to the central
station until the exit time has ended.