Installation guide

Advisor Master Programming Guide 81
User offset
User Offset Set to 0
Enter Offset
The offset is used to report user ID’s to management software. The offset is 0 to
65535. When a user ID is sent to the management package, this offset is added
or subtracted. The control panel itself uses the user ID without offset.
End of line resistor code
End Of Line Resistor Code 0
Code:
The End of line resistor code is used to set the correct value for the end of line
resistor used. By default this is set to 4,7 .
0: 10 kΩ
1: 4,7 kΩ
2: 2 kΩ
3: 6,8 & 6,98 kΩ
4: 5,6 & 5,7 kΩ
5: 3,74 kΩ
6: 3,3 kΩ
7: 2 kΩ
8: 1,5 kΩ
9: 1 kΩ not supported
10: 8,2 kΩ
Press 0 to skip further options and leave system options.
Duress mode
Duress Mode 0
Mode:
Defines the way to activate duress. Two options are available.
0: Increment last digit
1: No duress
Press 0 to skip further options and leave system options.
Siren Type
0: Speaker tone (standard AC tone)
1: Volts on (contant DC voltage)
2: Speaker or volts (multiple tone selection)
If siren type “0” has been selected, then when the 16th output is activated, a saw
tooth signal is generated at the signal output. If siren type “1” has been selected,
then when the 16th relay is activated, a constant DC voltage is set at the siren
output. If siren type “2” has been selected, then the 12th, 13th, 14th, 15th and
16th outputs are mapped to the siren output. These outputs have priority 1 to 5
respectively. Hence output 12 will have a higher priority over output 16 when