Installation guide
82 Advisor Master Programming Guide
both are active, thus generating a DC voltage at the siren output. The following
happens when the following output are activated:
• 12th output active = generates constant DC voltage at the siren output
• 13th output active = generates a warble tone at the siren output
• 14th output active = generates a sawtooth tone at the siren output
• 15th output active = generates 2 tones at the siren output
• 16th output active = generates an inverted sawtooth tone at the siren output
Inhibit alarm report on exit fault
YES-Inh. Alm. Rpt. On Exit Fault
*-Change 0-Skip
This option inhibits reporting of alarms with a reporting code of 17-24(burglar
alarm) when the exit timer is running. If set to Yes during the exit time, alarms on
inputs with reporting codes of 24 (burglar alarm) will set a flag to disable further
reporting. This is known as an ‘exit fault’. When the area is in Disarm, this flag is
reset. These inputs will log as ‘exit fault’ & ‘exit fault restore’ while the flag is set
or during the exit time. Burglar alarms in exit time will only activate the internal
siren.
Disable tamper report in disarm
YES-Disable Tamper Report in Disarm
*-Change 0-Skip
If set to Yes, a zone input tamper/restore will not report to the central station if
the assigned area(s) are disarmed. Similarly, system tampers/restores will not
report to the central station if all areas are disarmed. If a tamper occurs when the
area(s) are armed, this will report and send the restores when the areas are
disarmed.
Inhibit ext.sir&strobe for disarm tamper
YES-Inh. Ext. Siren & Strobe in Disarm
Tampers
*-Change 0-Skip
If set to Yes, zone input tampers will only activate the internal siren if the areas
are disarmed. System tampers operate similarly except that all areas are
disarmed.
ATS system code
ATS System Code
Code:
If the system code is 00000, the old algorithm is used to calculate the
engineering reset code. If not, the system code value and the engineering code
value are used in a special calculation to generate the reset code.
The default is set to 00000.