Installation guide

84 Advisor Master Programming Guide
Installer dual code
YES-Installer Dual Code
*-Change 0-Skip
This option enables installer access authorisation by valid system user.
If this option is set to Yes, then a second, user code must be entered before
access to any menu is granted. The second code must be a valid user code with
no access to the installer menu.
Enter User Code
Code:
The second user must have Alarm System Control and not have access to
menu 19. If the second user does not meet these conditions, then the display will
show:
You Are Not Authorised To Enter
Press ENTER
When Enter is pressed, the display will return to the user menu.
Note: The function does not work and user code is not requested:
When the system is in the Service In mode. See Manager Manual for more
details.
If PIN of the day option is set to Yes. See “PIN of the day optionon page 89.
Enable buzzer on mains/line fault
YES-Enable Buzzer on Mains/Line Fault
*-Change 0-Skip
Yes: Keypad buzzer will be sounded when there is a mains/line fault.
No: Only the LED will flash.
Enable "Call Central Station" display
YES-Enable Call Central Station
*-Change 0-Skip
Informs the Central Station in the event of opening or closing faults. In case of a
burglar alarm or tamper activation and when the “delay reporting alarms” timer
has expired, the user will be informed after disarming by the text “Call Central
Station” on the LCD if the reporting to the Central Station was successful. This
displayed message “Call Central Station” shall only be displayed for 30 seconds,
and is only displayed on RAS’s linked to the AREA or AREAs that went into
Alarm. The user can decide to call the Central Station to inform the status i.e. on
opening or closing faults.