Installation guide

Advisor Master Programming Guide 85
Exceptions
This text will not appear after reporting PANIC, HOLD-UP Alarms (HA) reports or
disarming by a Duress PIN. Also when a LINE FAULT is concurrently active, this
text will not appear.
Screen saver
YES-Screen saver
*-Change 0-Skip
Allows the user to enable or disable the screen saver.
Yes: Screen saver is enabled.
No: Screen saver is disabled.
Enable log limitations
YES-Enable Log Limitations
*-Change 0-Skip
Limits the number of repeating intrusion events from the same source within the
same arm/disarm cycle. A limit of three (3) times has been set.
Input types excluded from log limitations are as follows: 6, 7, 9, 12, 16, 18, 19,
20, 23 to 27, 31, 32, 34 to 39, 57, 58, and 65.
These types are generally associated with access control, or have a special
function, and are not associated with the normal alarm functionality.
Indicate inhibited zones
YES-Indicate Inhibited Zones
*-Change 0-Skip
Alerts the system user at the RAS with an optical and audible indication that
zones are inhibited in an area that is being armed. The inhibited zones need to
be listed and the user prompted with the option whether to arm the system or not.
Confirm area
1,2,4,5,7,8,
Confirm Area:
Defines areas to be processed as one alarm confirmation area (ACPO).
Eng Rst on ACPO zone B tamper
YES-Eng Rst on zone B tamper
*-Change 0-Skip
Enables engineer reset lockout for ACPO zone tamper B-alarms.