Installation guide
Advisor Master Programming Guide 87
Enable PA siren on FTC
NO-Enable PA Siren on FTC
*-Change 0-Skip
When set to Yes, and a Line Fault, or Fail-To-Communicate, condition exists, the
operation of a silent panic alarm changes to that of an audible panic alarm. When
the Line Fault, or FTC, restores, the silent panic alarm reverts to silent operation.
Latch AWDGP jam and supervision
NO-Latch AWDGP Jam and Supervision
*-Change 0-Skip
When set to Yes, and at least one area of the control panel is armed, the
jamming alarm condition will latch, and a user code is required to reset the
condition. To reset the jamming alarm, the user alarm group must permit the
reset of system alarms.
When this option is set to Yes, and the area with the AWDGP zone assigned is
armed, the long supervision / smoke supervision alarm on that zone will latch,
and a user code is required to reset the condition. To reset the long supervision /
smoke supervision alarm, the user alarm group must permit alarm reset.
When this option is set to No, the jamming alarm and supervision/smoke alarm
conditions are self-resetting when the condition restores. Regardless of this
setting, when the area is disarmed, only a device tamper condition will latch. All
other AWDGP fault and alarm conditions are non-latching, and automatically
restore when the condition clears.
Enable chime
YES-Enable Chime
*-Change 0-Skip
When set to Yes, chime/camera events are treated as chime events in Zones
and Areas databases. Otherwise these events are treated as camera events.
This menu toggles between chime and camera event flag operation. When this
menu is set to Yes the chime/camera event flag, programmed in the zone and
area databases, is treated a chime event. When this is set to No, this event flag
is a camera event.
• Set this option to Yes,
• Ensure the zone type selected for chime can accept the chime function (see
“Zone type” on page 7),
• Enable the “Trigger chime/camera EF in area DB” on page 25 in the Zone
database for all chime zones,
• Programme a “Chime/camera event flag” on page 31 in the Area database,
• Programme the required Chime duration in Timers > “Chime time is set to” on
page 68,