Installation guide
88 Advisor Master Programming Guide
• Programme the activating device for chime. Options: programme in the area
database a Chime activated RAS number (see “Chime on RAS” on page 38),
or assign the chime event flag to the keypad buzzers in System flags (see
“Keypad buzzer event flag” on page 153), or assign the Chime event flag to
an output number.
Synchronize DGP users records
YES-Synchronize DGP users records
*-Change 0-Skip
Synchronization allows restoring user record in DGP user database, if the card
number is missing.
If the DGP does not recognize a badge card, it queries this card in the ATS
panel. If the user exists in the ATS panel user database, the panel resends this
record to all DGPs.
This functionality allows connecting four-door DGP to the ATS panel without
downloading user database. Four -door DGP automatically learns user PINs,
alarm groups, etc. when a user presents his card first time.
Engineer reset on RAS lockout
NO-Engineer reset on RAS lockout
*-Change 0-Skip
If the Engineer reset on RAS lockout option is set to Yes, an engineer reset is
required to unlock a RAS lockout. Otherwise, the RAS is unlocked normally.
See also “Timed lockout by wrong codes” on page 44.
For more information on engineer reset, refer to “Engineer reset for system
alarms” on page 79 and “User can do engineering reset” on page 80.
Prevent arming on faults
YES-Prevent arming on faults
*-Change 0-Skip
Setting to Yes prevents arming on faults and events listed in the list below:
• Detector in active condition
• Tamper condition
• Detector range reduction
• Interconnection fault
• Auxiliary power source fault
Note: “Ignore battery fault when arming” on page 80 must be set to No.
• Primary power source fault
Note: “Ignore AC mains fault when arming” on page 86 must be set to No.
• Communication module fault