Installation guide

Advisor Master Programming Guide 89
Watchdog fault
Exit fault
Other alarm system component fault
The default is Yes.
PIN of the day option
Caution: Once this option is switched to Yes, it cannot be switched back to No.
YES-PIN Of The Day Option
*-Change 0-Skip
If PIN of the day option is set to yes, the installer can only enter the system with a
response code, which can be obtained from the appropriate security manager.
The code is calculated basing on the PIN of the day that is generated for the
particular session.
How to log in the system when the PIN of the day option is set to Yes:
1. Log in as an installer.
The following screen appears:
Challenge Code. Press ENTER
1234567890
2. Contact the security manager and give him the PIN of the day. Using
dedicated code calculating software, he generates the response code from
the Challenge code.
Press Enter.
Enter Response Code
PIN:
3. Enter response code, and then press Enter.
A single response code is valid during the time period defined in “Access time for
PIN of the dayon page 68.
Override AC mains fail
YES-Override AC Mains Fail
*-Change 0-Skip
If set to Yes, the user can manually override AC mains fault when arming.
The default value is Yes.