Installation guide

Advisor Master Programming Guide 91
Override RAS fault
YES-Override RAS Fault
*-Change 0-Skip
If set to Yes, the user can manually override RAS fault when arming.
Note this does not apply for RAS offline scenario. (Offline RAS must be isolated
by installer to proceed arming).
The default value is Yes.
Override DGP fault
YES-Override DGP Fault
*-Change 0-Skip
If set to Yes, the user can manually override DGP fault when arming.
Note that the overriding does not work if DGP is offline. Offline DGP must be
isolated by installer to proceed arming.
The default value is Yes.
Enable buzzer on alerts
NO-Enable buzzer on alerts
*-Change 0-Skip
If set to Yes, the keypad provides a 5-second audible alert when user action is
necessary on a keypad in a disarmed state, usually when unacknowledged
alarms or faults are present. The alert reactivates after each period of time
programmed in “Local alarm reminder timeon page 64.
The audible alert only works on a keypad if:
All areas assigned to the RAS are disarmed, and
There are unacknowledged alarms or faults at least in one of areas assigned
to this RAS.
To silence the buzzer once, press Clear.
See Advisor Master User Guide and Advisor Master Manager Manual for more
information on local alarms.
Internal siren on exit fault
NO-Internal siren on exit fault
*-Change 0-Skip
If set to Yes, an internal siren is activated if an exit fault has occurred.