Operating instructions

The Control Unit LEDs 1-8 will indicate the new House
Code switch setting eg.
Press to memorise the House Code setting and to
revert to the Test/Programming mode.
2. INSTANT/DELAY ZONE
Any Zone can be set to give an Entry Delay when
the appropriate detector(s) are triggered, eg. to allow
access to the Control Unit for manual Disarming.
(The length of the entry delay period is programmed
separately - see 3 below).
With the Control Unit in Test/Programming mode
Enter
The Zone LEDs 1-4 and Zone 5 (Tamper/Personal
Attack) LED will indicate the status of each Zone:-
Zone LED ‘ON’ = Delay Zone
Zone LED ‘OFF’ = Instant Zone
Factory default:-
Zone 1 Entry Delay
Zone 1 LED ‘ON’
To add or delete a Delay Zone, press the number of
the Zone to illuminate or extinguish the appropriate
Zone LED.
Note: The Hard-wired input Zone (Zone 5) can also be
set for instant or delay operation and its status will be
indicated by the Tamper/Personal Attack Zone LED
being ‘ON’ or ‘OFF’.
Press to memorise the setting and to revert to the
Test/Programming mode.
3. EXIT/ENTRY DELAY TIME
When the system is Fully Armed either at the Control
Unit or via a Remote Control, the system will ignore all
detectors for the Exit/Entry Delay time, to allow you to
leave the premises.
Similarly, when entering an Entry Delay Zone with the
system Armed or Part Armed, the system will be
inactive for the Exit/Entry Delay time to allow you time
to Disarm the system by entering your Access Code at
the Control Unit, or using the Remote Control.
Note: The Exit and Entry Delay times cannot be
individually programmed to different settings. The Exit
delay when the system is Part Armed is preset to 30
seconds and cannot be changed. However, the Entry
Delay time will be the same as that set for Full Arm
operation.
With the Control Unit in Test/Programming mode
Enter
A Zone LED will illuminate to indicate the setting:-
Factory default:-
30 seconds - Zone 3 LED ‘ON’
To change the setting, press the appropriate key to
illuminate the associated Zone LED:-
Note: 50 seconds setting will be indicated on
Tamper/Personal Attack/Zone 5 LED.
Enter to memorise the setting and to revert to the
Test/Programming mode.
4. ALARM AUTOSTOP TIME
This is the length of time that the alarm will sound for
when activated. (If accidently triggered, the alarm can
be stopped at any time using the Remote Control or by
Disarming at the Control Unit keypad).
Note: The maximum length of time that the External
Solar Siren & Strobe will sound for when activated is set
within the Solar Siren & Strobe to either 3 or 15 minutes
- refer to ‘Installing and Setting the External Solar Siren
& Strobe’ for details.