Operating instructions
With the Control Unit in Test/Programming mode
Enter
A Zone LED will illuminate to indicate the setting:-
(factory default 3 minutes - Zone 3 LED ‘ON’). To
change the setting press the appropriate key to
illuminate the associated Zone LED:- (Note: 10 minutes
setting will be indicated on the Tamper/Personal
Attack/Zone 5 LED).
Press to memorise the setting and to revert to the
Test/Programming mode.
5. PART ARM/ZONE OMIT
Any of the Zones 1-5 can be omitted (ie. made in-active)
when the system is Part Armed. This will enable you to
Arm only the selected (active) Zones when you Part Arm
the system.
With the Control Unit in Test/Programming mode
Enter
The Zone LEDs 1- 4 and Tamper/Personal Attack/Zone
5 LED will illuminate to indicate the Zones which are
OMITTED (in-active) when the system is Part Armed:-
Factory default:-
Zones 3 and 4 omitted - Zones 3 and 4 LEDs ‘ON’
(ie. Zones 1, 2 and 5 are Active in Part Arm)
To add or delete an omitted Zone, press the number of
the Zone to illuminate or extinguish the appropriate
Zone LED.
Press to memorise the setting and to revert to the
Test/Programming mode.
6. EXIT/ENTRY DELAY TONES
During the Exit/Entry delay periods the Control Unit may
be set to either emit a constant Exit/Intermittent Entry
bleep tone or two short bleeps at the beginning and end
of the delay time (semi silent), depending on the
programming.
With the Control Unit in Test/Programming mode
Enter
Zone 1 LED will indicate the setting:-
LED ‘ON’ - constant Exit/Intermittent Entry bleep
tone selected
LED ‘OFF’ - semi silent Exit/Entry bleeps selected
Factory default:-
Constant Exit/Intermittent Entry bleep tone ‘ON’ - Zone 1
LED ‘ON’
Press as required to select the delay tone required
Press to memorise the setting and revert to the
Test/Programming mode.
7. JAMMING DETECTION SYSTEM
In order to detect any attempts to illegally Jam the radio
channel used with your alarm system a sophisticated
Jamming Detection system is incorporated into the
Control Unit. If this feature is selected and the radio
channel is continuously jammed for more than 30
seconds, when the system is Armed or Part Armed, the
Control Unit sounder will emit a pre-alarm series of
rapid bleeps for 5 seconds. If the Jamming continues
for a further 10 seconds or more, a Full Alarm will occur
indicated by the Internal and External Alarms sounding
and the Tamper/Personal Attack Zone LED illuminating.
The Jamming Detection circuit is designed to scan for
jamming signals. However, it is possible that it may
detect other local radio interference operating legally or
illegally on the same frequency. If it is planned to
operate the jamming detection feature we recommend
that the system is monitored for false jamming alarms
for at least 2 weeks prior to leaving the Jamming Detect
function on permanently.
With the Control Unit in Test/Programming mode
Enter
Zone 1 LED will indicate the setting:-
LED ‘OFF’ - Jamming Detection system ‘OFF’
LED ‘ON’ - Jamming Detection system ‘ON’
Factory default:-
Jamming Detection ‘OFF’, Zone 1 LED ‘OFF’
Press as required to select the Jamming Detection
‘ON’/‘OFF’
Press to memorise the setting and revert to the
Test/Programming mode.
1
1
minute
Press
Alarm
Time
2
minutes
3
minutes
5
minutes
10
minutes
2345
4
7
5
6
1
1
16 Eclipse E400