Operating instructions
Details of Control Unit Terminal Block
OPERATING
INSTRUCTIONS
FULLY ARMING THE SYSTEM
When leaving the premises, the system must be Fully
Armed. However, before doing so, check that all
windows are closed and locked, all protected doors
are closed and Passive Infra Red Movement
Detectors are not obstructed. Ensure that pets are
restricted to areas not protected by Passive Infra Red
Movement Detectors or that suitable precautions
have been taken to allow for pets.
The system may be Fully Armed either at the Control
Unit or using a Remote Control. To Fully Arm at the
Control Unit
Enter
To Fully Arm the system from a Remote Control simply
press the ‘ON’ button.
If the system has been programmed for a constant
Exit/Entry Delay tone, the Control Unit will emit a
continuous tone for the duration of the Exit time Arming
automatically when the Exit time expires.
If the system Exit/Entry Delay tone has been set for
‘Semi Silent’, the Control Unit will emit two bleeps,
followed by two bleeps on expiry of the Exit time.
All occupants must leave the premises before the Exit
time has expired. If for any reason you are unable to
leave the premises before the Exit time has expired,
you will need to Disarm the system, then Re-Arm.
Failure to do so will cause a Full Alarm if any protected
door is opened or movement is detected by a Passive
Infra Red Movement Detector.
Note: When Fully Armed, the Control Unit ‘System
Status’ LED will be constantly illuminated.
PART ARMING THE SYSTEM
If you are remaining in the premises, you may Arm all
the Zones which have not been omitted, by selecting
Part Arm. This will permit free access to the omitted
Zone areas.
The system may only be Part Armed from the Control
Unit. The Part Arm Exit time is preset to 30 seconds.
To Part Arm the system
Enter at the Control Unit.
The LEDs associated with the Part Arm Zone(s)
will illuminate for 30 seconds. (Any Zone LED not lit
indicates that the Zone has omitted and will not be
active in Part Arm mode).
In addition, the Control Unit will emit two bleeps,
followed by two bleeps on completion of the 30 second
Exit time.
Note: Zone 5 ‘Active’ will be indicated by the
Tamper/Personal Attack/Zone 5 LED illuminating.
After the 30 second Exit time the LEDs will extinguish.
You must leave all protected Zones before expiry
of the 30 second Arming time. If for any reason you
are unable to leave the protected areas within the
Arming time, you will need to Disarm the system then
Re-Arm. Failure to do so will cause a Full Alarm if
any protected door is opened or movement is
detected by a Passive Infra Red Movement Detector
set to operate in Part Arm.
Note: When Part Armed the Control Unit ‘System
Status’ LED will be flashing.
POWER –
POWER
+
N.O.
COM
N.C.
SIREN (
+
)
COM (–)
TAMPER
COM
WIRE ZONE
BATTERY –
BATTERY
+
1
2
3
4
5
6
7
8
9
10
11
12
Factory
Link
12 Vold DC
Permanent Supply Output
Latching Relay
Change-over Contacts
12 Volt DC
Output On Alarm
Hard-wired Siren Tamper Circuit/
Negative Tamper Return
(Siren Tamper Return Link must be set to
the 'ON' position when connection made)
Hard-wired Zone 5 Input
(Remove Link and Wire In
Normally Closed Circuit)
12 Volt DC
Permanent Supply Input
(Not used in the UK)
????
Access Code
????
Access Code
18 Eclipse E400