Operating instructions

TROUBLE SHOOTING
Control Unit not working. Mains light is off
1. Press key on Control Unit. If mains light illuminates
and then extinguishes after 10 seconds this indicates
the Control Unit is operating on Back-up Battery.
2. Check that mains adaptor is plugged in/connected
and switched on.
Full Alarm Occurs when alarm has not been
activated by an intruder
1. Ensure mains adaptor is plugged in/connected and
switched on.
2. Check that battery covers on all detectors are fitted
securely.
3. Ensure that the Control Unit is securely fitted to the
wall and that the front cover is firmly closed.
4. Check that the Personal Attack Button or Smoke
Detectors (if fitted) have not been operated.
5. Check for Jamming Detection Alarm.
Control Unit ‘Low Battery’ LED illuminated
1. Check all PIR Detector(s) for low battery, indicated
by detector LED flashing when movement is
detected - change battery(s) as required.
2. Check all Magnetic Detectors for low battery
indicated by detector LED not illuminating when
detector is opened/closed - change batteries as
required.
3. Check the battery in all Optional Wirefree Smoke
Detectors - a low battery will also cause the Smoke
Detector to bleep every minute - change battery as
required.
Detection Zone has been triggered but no
alarm is sounding
1. Entry Delay Zone triggered - alarm will sound when
delay time has expired.
2. Zone omitted when part armed.
Control Unit will not function
(Sirens are sounding)
1. Disconnect power (including Control Unit Back-up
Battery), for 10 seconds, then re-connect mains
power followed by Back-up Battery. (Remember, all
programmed functions will be retained if the
Memory Link is in the ‘ON’ position).
Control Unit not accepting Access Code
1. Pausing too long between pressing keys. Do not
pause for more than 5 seconds between keys.
2. Incorrect code entered. Allow 5 seconds to elapse
before re-entering correct code.
3. Unit has reset to factory default codes/programme.
Fit Memory Link in ‘ON’ position and re-programme
all programmable functions.
Control Unit not responding to detectors
1. Ensure detectors are within radio range of Control
Unit. If not, move detector closer.
2. Ensure that the House Code on the detector is the
same as that set in the Control Unit.
3. Replace detector battery.
Solar Siren and Strobe sounding but no
alarm at Control Unit
1. Siren Anti-tamper activated. Check security of
Siren/Strobe fixing to wall and that Siren anti-
tamper switch is fully depressed.
2. Siren & Strobe has not received ‘Stop’ signal.
Press ‘Panic’, wait 15 seconds then press ‘OFF’
on Remote Control to re-transmit ‘Stop’ signal.
Solar Siren and Strobe does not operate
when system is activated
1. Incorrect Siren Code dip switch settings in Solar
Siren & Strobe or Siren Code incorrectly
programmed into Control Unit.
2. Siren duration time timed-out before Control Unit
Autostop time.
3. Disconnect rechargeable and power-up batteries.
Cover solar panel and leave unit for 3-5 minutes.
Re-connect the batteries and then remove the solar
panel cover.
4. Rechargeable battery low. Power down, fit new
initial power up battery and re-power up.
No response from Passive Infra Red
Movement Detector
1. Check battery connections are good.
2. Ensure that House Code is same as that set in
Control Unit.
Symptom
/
Recommendation Symptom
/
Recommendation
22 Eclipse E400