6 Zone Wireless Security Alarm SL3 / SL8 ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FIRE TAMPER POWER PART ARM ARM LOW BATT.
FOREWORD All devices in this wireless Alarm System are designed and manufactured to provide long reliable service. The system is designed for ease of installation using only conventional domestic tools. However, it is essential that the installer reads and fully understands the advice and procedures contained in this manual and plans the system before proceeding with the installation. During installation, it is important that the procedures described in this manual are followed in sequence.
CONTENTS KIT CONTENTS 4 Power-up of the Solar Siren Linking the Solar Siren to the Control Panel 20 21 INTRODUCTION AND OVERVIEW 5 Testing the Wireless Solar Siren 21 System Arming 5 Mounting the Solar Siren on to the wall 21 Entry/Exit Delay 5 Zones 5 Zone Lockout 5 Tamper Protection 5 Jamming Detection 6 Battery Monitoring 6 User Access Code 6 PLANNING AND EXTENDING YOUR ALARM SYSTEM Typical Installation 6 SPECTRA LIGHTING RECEIVER Linking the Control Panel to the Spectra Light
KIT CONTENTS The Alarm System should contain the following devices. SL3 SL8 Solar Siren 1 1 Control Panel 1 1 Remote Control 0 1 PIR Movement Detectors 2 2 Door / Window Detectors 2 2 Also included: Siren Mounting Template Installation & Operating Manual Fixing pack Batteries Please Note: An installation video is available on-line at www.friedlandproducts.com Solar Siren ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FIRE TAMPER POWER PART ARM ARM LOW BATT.
INTRODUCTION AND OVERVIEW SYSTEM ARMING The system has a ‘Full Arm’ and a ‘Part-Arm’ facility. Full Arm will arm all zones while the ‘Part-Arm’ mode until after the Entry/Exit period has ended. If the system is not disarmed during the delay period, the alarm will sound when the delay period expires. will only arm the zones that are selected and enabled for “Part-Arm”. Instant Armed zones are immediately able to initiate an alarm as soon as the system begins to arm.
the alarm even if the system is Disarmed (unless the system is in Test or Program modes). JAMMING DETECTION In order to detect any attempts to illegally jam the radio channel used by your alarm system, a special jamming detection function is incorporated into the Control Panel. If this feature is enabled, an alarm will be triggered if the radio channel is jammed continuously for more than 30 seconds or if the system is jammed for more than 3 periods of 10 seconds in a 5 minute period.
ZONE 1 A ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FIRE TAMPER POWER PART ARM ARM LOW BATT. 1 2 3 4 5 6 7 8 9 ! 0 ESC ENTER E Control Panel C C B D C A D Remote Control D C B SHED PIR Movement Detector D D Back Door C KITCHEN D DINING ROOM Magnetic Door/Window Detector HALL LOUNGE A D D GROUND FLOOR GARAGE E C External Solar Siren protection.
REMOTE CONTROL UNIT The Remote Control Unit(s) is used to Arm in either Arm or Part Arm modes and to Disarm the system. Instant-Arm Disarm Transmit LED Insert a small coin into the slot on the edge of the housing to gently lever open Delay-Arm Battery Clip Battery Personal Attack Button Press and hold for 3 seconds TESTING THE REMOTE CONTROL The Remote Control Unit also incorporates a Personal Attack (PA) button.
3. It is recommended that the Control Panel should be positioned such that the Exit/Entry tone (emitted by the Control Panel) can be heard from outside the property. 4. The Control Panel should be mounted within a protected area so that any intruder cannot reach the Control Panel without opening a protected door or passing through an area protected by a PIR Detector when the system is armed. 5. The Control Panel must be located within reach of a mains socket. 6.
Control Panel over these screws using the two keyhole slots in the top corners of the panel casing. 5. Route the cable from the Power Supply Adaptor up behind and on the right hand side of the Control Panel and connect the plug to the DC power socket in the panel. Ensuring that the cable is not trapped between the panel and the wall. 6. Fix the Control Panel to the wall using two 18mm No.
2. Press the Control or button on the new Remote Press ? ? ? , ? To delete all linked Remote Controls/Keypads from the Control Panel: 1. Keypad User Access Code on the Remote Keypad. Place the Control Unit into Learn Mode. With the system in Standby , Press ? ? ? , ENTER User Access Code If the Remote Control/Keypad is new and not already linked the panel will produce a two short beeps and the next available zone LED will start flashing, (once every second).
Activate the Personal Attack switch on the Remote Control. The Control Panel alarm will sound and all Zone/Fire/Tamper LEDs will flash. 4. Disarm the system by pressing the button on the Remote Control. The Control Panel alarm will stop. The LEDs will continue to flash. 5. Press on the Control Panel to return to Standby and cancel any warning LEDs. 6.
4. Where possible, mount the Detector in the corner of the room so that the logical path of an intruder would cut across the fan detection pattern. PIR Detectors respond more effectively to movement across the device than to movement directly towards it. 5. Do not position the Detector in a position where it is subject to excessive vibration. 6. Ensure that the position selected for the PIR Detector is within effective range of the Siren. 7.
6. Connect the PP3 Alkaline battery to the battery clip. The LED behind the lens will rapidly flash for approximately 2-3 minutes until the PIR has stabilised. The LED will then stop flashing and turn OFF. TESTING THE PIR DETECTORS 7. Ensure that the LED indicator has stopped flashing rapidly. 8. The ‘Test Mode’ button (SW1) is used to put the PIR Detector into Walk Test mode, which overrides the 2 minute sleep period and allows the operation of the detector to be checked during installation.
POSITIONING THE DOOR / WINDOW DETECTORS The Door / Window Detector is suitable for mounting in dry interior locations only. 2. Slide the two batteries supplied into the battery holder, ensuring that the + side is uppermost on each battery as it is installed. 3. If necessary, refit the battery holder into the detector ensuring that the spring clip connectors slide onto either side of the circuit board.
The wired contact should be connected using a maximum length of 1.5 metres of any of the following: simultaneously (INT./EXT. position), only one activation will be counted if one of the contacts is opened. If one contact is left open and the other closed contact is opened then an activation will be counted. – 6 core alarm cable – 2 core bell wire (6 x 0.2mm minimum) If using external contacts wired to the Detector, set to the INT./EXT. position.
LEARNING ZONE DETECTORS Note: A maximum of 3 PIR or MAG detectors can be linked to each alarm zone. A detector cannot be linked to more than one zone. To link a new PIR/MAG Detector to the Control Panel: 2. Place the Control Panel into Learn Mode as follows: If the detector is new and not already linked on any security zone the panel will produce two short beeps and the next available zone LED will start flashing, (once every second).
3. Press again within 15 seconds to confirm and erase the device links. To link a new Smoke Detector to the Control Panel: The flashing zone LEDs will extinguish. 3. ENTER If the detector is new and not already linked on the fire zone the panel will produce a two short Note: If the erase is not confirmed within 15s the LEDs will stop flashing and remain illuminated. All links will remain intact and will not be erased. 4. beeps and the next available zone LED will start flashing, (once every second).
The flashing zone LEDs will extinguish. Note: If the erase is not confirmed within 15s the LEDs will stop flashing and remain illuminated. All links will remain intact and will not be erased. 9. Press 10. Press ENTER ESC to save new settings and exit or to exit without saving. EXTERNAL SOLAR SIREN The Siren is encapsulated within a tough polycarbonate housing that also provides full protection against adverse weather conditions.
Siren Switch SW3 ALARM TIME ALARM TIME AJ BEEP SOUND C.U. OR SIREN ALARM SOUND 5 DIP switch 1 marked “ALARM TIME” is used to limit the maximum period for which the external siren will sound before it will be automatically shut down, (even if the Control Panel is still in alarm): ON 10 minutes OFF 3 minutes DIP switch 2 marked “AJ” does not function for this system and should be ignored. 6.
After 10s the “Siren Stop” signal will automatically be retransmitted by the Control Panel for the LINKING THE SOLAR SIREN TO THE CONTROL PANEL siren to confirm the control panels ID code. When you power up the siren it will automatically be in Service Mode. It cannot be switched out of Service Mode or respond to the control panel until the control panels has been linked to it and the panels ID code learnt into the siren’s memory. The siren needs to be placed into Learn Mode to complete this.
8 and 10. Now press Mode ON. ENTER to switch Service The siren will produce two short beeps followed 1 second later by a single long beep. The Siren LEDs will flash together in conjunction with the beeps. SPECTRA LIGHTING RECEIVER LINKING THE CONTROL PANEL TO SPECTRA LIGHTING RECEIVER 1. 11. Fit the keyhole slots in the top of the siren over these screws and check that they form a neat fit with minimal movement. If necessary remove the siren and adjust the screws as required.
EXTERNAL CONNECTIONS (Optional) To do this: The Control Panel incorporates a terminal block for connection of a Hard-wired Siren. The connection terminal block is located inside the Control Panel behind the front cover. To access the terminal block you must first put the system into Test Mode to prevent an alarm occurring. Press External Tamper Switch Jumper Link P51 Terminal Block , 1 2 3 4 , ENTER User Access Code The Arm and Part-Arm LEDs will flash.
TESTING THE SYSTEM The Control Panel has a built in test facility to enable you to test the system at any time. However it is recommended that the system is tested at regular intervals not exceeding 3 months. 3. With the system in Standby 4. , Press 1 2 3 4 , Press on the Remote Control: The Control Panel will beep and the PART-ARM LED will flash. Press on the Remote Control: The Control Panel will beep and the ARM and PART-ARM LED’s will flash.
WIRE FREE SIREN TEST Press 2 ENTER The External Solar Siren will be activated for 5 seconds and then stop. Zone 2 LED will be illuminated during the test.
PROGRAMMING INSTRUCTIONS With the system in Standby (i.e. with the Power LED ON) Default setting: 3 minutes Press , Press ? ? ? ? , 1 ENTER The zone LED corresponding to the current setting will illuminate. User Access Code Note: To get to Standby Mode simply press repeatedly until only the POWER LED is illuminated. ESC 0 no alarm 1 1 minute The Arm and Part-Arm LEDs will illuminate and all 2 2 minutes Zone, Fire and tamper LEDs will flash together.
Press to save the new setting and exit to Program Mode, or ENTER Press ESC to exit without saving. To change the setting: Press 1 The warning tone status will switch to the opposite state each time the button is pressed. INSTANT/DELAY ZONES Press to save the new setting and exit to Program Mode, or ENTER This defines which zones will operate in conjunction with the systems entry/exit delay period and which zones will instantly trigger an alarm when activated while the system is armed.
The zone 1 LED will illuminate to indicate the current Zone Lockout status. LED ON Zone Lockout enabled LED OFF Zone Lockout disabled To change the setting: Press 1 The Zone Lockout status will switch to the opposite state (enabled/disabled) each time the button is pressed.
OPERATING INSTRUCTIONS When leaving the premises, the system must be Armed. However, before doing so, check that all windows are closed and locked, all protected doors are closed and PIR Detectors are not obstructed. Ensure that pets are restricted to areas not protected by PIR Detectors. – If the Solar Siren is fitted and the 3 minute limit is enabled then the siren will stop when the programmed alarm duration expires or after 3 minutes, whichever occurs first.
PERSONAL ATTACK (PA) ALARM Notes: An Alarm can be immediately triggered at any time (whether the system is Armed or Disarmed) in the event of threat or danger by activating a Personal Attack (PA) switch on either the Remote Control or the Control Panel as follows: 1. The fire alarm sound will be different to that generated from an intruder alarm. a. Press and hold the 3 seconds or button for b. Press and hold the 9 button for approximately 3 seconds on the Control Panel.
Service Mode: The siren will produce two short beeps followed 1 second later by a single long beep. The Siren LEDs will flash together in conjunction with the beeps. Press ESC to return to Standby. SIREN OPERATING MODE The Siren can be switched back into Operating Mode using either the Remote Control or Control Panel as follows: Remote Control: Press and hold the approximately 5 seconds.
the Detector is in Test Mode with the battery cover removed). The indicator on the Control Panel can be cancelled by pressing . The LED will start flashing on receipt of the next low battery signal. ESC SPECTRA PLUS LIGHTING If the Control Panel is liked to a Spectra plus Lighting Receiver and the Spectra Lighting Control is enabled then any alarm condition (except Fire alarms) will cause the linked lighting to be switched on for the set light-on duration.
MAINTENANCE Your Alarm System requires very little maintenance. However, a few simple tasks will ensure its continued reliability and operation. SOLAR SIREN 1. It is recommended that the solar panel on the top of the siren housing should be cleaned at least twice a year, preferably in the Spring and Autumn, using a soft damp cloth. Do not use abrasive, solvent based or aerosol cleaners. Do not attempt to clean inside the unit or allow water to enter the unit.
TROUBLE SHOOTING Symptom / Recommendation Control Unit not working – Power LED OFF or flashing. Siren and Indicator LEDs operating but no alarm at Control Panel. 1. Mains power failure - check if other electrical circuits are operable. 1. Siren’s Tamper switch activated. Check security of Siren fixing to wall and adjustment of anti- 2. Check that mains adaptor is plugged in and socket is switched ON. tamper switch to ensure switch is fully depressed. Siren not responding to Control Panel. 3.
LED on Remote Control not illuminating, or is dim when unit is operated. PIR Detector LED flashes on detection of movement, (device in normal operation mode). 1. Ensure battery is fitted with correct polarity. 1. PIR still in Walk Test Mode for fixed 5 minutes if the PCB button was activated. 2. Ensure battery holder connections are making good contact with the battery. 2. Low battery - replace battery. 3. Battery flat - replace battery. Door / Window Detector not working.
CUSTOMER HELPLINE Most issues can be solved over the phone in a few minutes. Please contact our Helpline Team on the number below for any installation and general advice regarding our products: 0844 736 9149 Lines open 9.00am to 5.00pm, Monday to Friday. Calls charged at service providers national rate. EXTENDING YOUR ALARM SYSTEM The following additional accessories are available to enhance your system and provide further protection and a higher level of security where required.
GUARANTEE Novar ED&S undertakes to replace or repair at its discretion goods (excluding non rechargeable batteries) should they become defective within 1 year solely as a result of faulty materials and workmanship. Understandably if the product has not been installed, operated or maintained in accordance with the instructions, has not been used appropriately or if any attempt has been made to rectify, dismantle or alter the product in any way the guarantee will be invalidated.
NOTES 38
NOTES 39
COMPONENT SPECIFICATION External Solar Siren Control Panel ZONE 1 300 mm ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FIRE TAMPER POWER PART ARM ARM LOW BATT. 1 2 3 4 5 6 7 8 9 External Lighting Control (Optional) 187 mm ! 0 218 mm ● ● ● ● ● ● ● ● ● ● ESC 148 mm ENTER 235 mm 94 mm RF operating frequency: 868MHz Sealed lead acid battery 6V /1.2Ahr Solar Panel 7.