models #RVL50, RVL70, RVL80, RVL90, RVL110, RVL130, RVL150 Installation Guide Read and Save These Instructions Need Help? Watch the installation video at: reventfans.
Please Read and Save These Instructions Table of Contents page 1 ............... Table of Contents page 1-2 ........... Specifications page 3 ............... What’s Inside The Box page 4 ............... Safety Information page 5 ............... Planning Your Installation page 6 ............... Connecting The Duct page 7 ............... Removing Your Old Fan page 8-13 .......... SheetLock™ Easy Roomside Installation page 14-19 ........ Installation For New Construction Framing page 19 .............
RVL90, RVL110 Duct Exhaust Diameter 4 in ( 10.2 cm ) Voltage 120 V Frequency 60 Hz Fan Watts 23 W, 30 W LED Watts 13.5 W LED Brightness 1000 Lumens LED Color Temp 4000 Kelvin Air Flow 90 CFM, 110 CFM Fan Weight 6.95 Lbs ( 3.15 Kg ) Sound 0.7 Sone, 1.3 Sone Grille Size 12 5/8 x 12 5/8 in ( 32.1 x 32.1 cm ) Housing Length* 9 3/4 in ( 24.8 cm ) Housing Width* 9 1/2 in ( 24.1 cm ) Housing Depth* 6 3/8 in ( 16.2 cm ) *This may require modification of your current opening.
What’s Inside The Box DAMPER Qty:1 FAN Qty:1 GRILLE Qty:1 Tape this to the ceiling. Insert jab saw or pencil in slot, and cut or mark. Use template slot to guide saw or pencil. Fixez ce gabarit au plafond avec du ruban adhésif. Servez-vous de la fente pour marquer avec un crayon ou pour découpe avec une scie pour plaque de plâtre. Pegue esto en el techo. Inserte una sierra para paneles o lápiz en la ranura y corte o marque. Utilice una plantilla para ranuras para guiar la sierra o el lápiz.
Safety Information 1.) WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.
Planning Your Installation When installing the ventilation fan in a new construction site, install the main body of the FAN and duct work during the rough-in construction of the building. The GRILLE should be installed after the finished ceiling is in place. When installing in existing construction, use the provided cutout TEMPLATE for the ceiling. GRILLE edge should overlap finished ceiling. Not for use in cooking area - see diagram below.
Connecting the Duct ● Install a circular duct to outlet and secure it with duct tape or clamps. ● Install the duct to the outlet with a gradient 1°~2° to the outside as shown. ● ● ● ● ● ● The ducting from this FAN to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the FAN with smaller ducts than recommended.
Removing Your Old Fan 1.) Disconnect the electrical power supply and lock out the service panel for the existing fan. 2.) Remove the grille from the existing fan. Pull the grille down to expose it’s two springs. Squeeze each spring together and pull down again to release the springs from the motor plate slots. 3.) Your existing fan may be attached in several ways. Look for attachment screws in the ceiling and remove.
SheetLock Easy Roomside Installation TM Watch the video: REVENTFANS.COM/INSTALL WARNING: Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling. 1.) Place the provided sheetrock cutout TEMPLATE on ceiling where you wish the FAN to be (DAMPER and electrical positions shown on TEMPLATE). We suggest using painter’s masking tape to hold the template in place while cutting. If there is a pre-existing fan opening, use aligning windows to find it’s edges.
3.) Attach DAMPER to ducting. Tape DAMPER to ducting with duct tape. Set the connected DAMPER and ducting in the ceiling opening, then set the FAN in the ceiling opening as well. Connect DAMPER and ducting with duct tape FAN ducting DAMPER Place FAN and DAMPER inside CEILING opening ceiling 4.) Attach conduit with wiring to FAN. FAN conduit ceiling 5.) Reattach DAMPER to FAN inside the ceiling, damper should click into place securely. FAN DAMPER ducting conduit ceiling 6.
7.) Bend the holding tabs you selected outward. 8.) Set FAN into place in the opening using holding tabs, now the tabs hold the fan in position in the ceiling opening. holding tab holding tab holding tab WARNING: Disconnect the AC power before any work is done to any part of the circuit ReVent is connected to. If you do not understand this warning, seek the services of a qualified licensed electrician. WARNING: Copper to copper only. Do not use aluminum wire.
Match wire colors as shown: line ground line neutral line ground FAN ground housing ground line in light line neutral light line in FAN FAN FAN neutral light neutral SWITCHES NOT INCLUDED, MUST BE PURCHASED SEPARATELY Always follow all safety instructions included with the switch you purchase. Do not exceed maximum electrical ratings.
11.) Once connected, reattach the electrical enclosure. plug in connectors reattach set screw 12.) Press and bend the final securing tabs flat against ceiling to lock the FAN in place. final securing tabs apply even pressure to each side of securing tab sheetrock (ceiling) 13.) Align TRIM RING notch to vent (DAMPER) position. Attach TRIM RING to FAN. TRIM RING attaches to FAN body and clicks into place when secure.
.) Connect GRILLE wire to FAN. Attach the GRILLE by squeezing the mounting springs together and inserting the springs into the spring guides in the FAN.
Installation For New Construction Framing NOTE: Even with new construction, you can use the SheetLock™ installation method; however, ReVent can still be installed using a method home builders would be more familiar with, as outlined in this section. WARNING: Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling. 1.) Select a set of holding tabs, depending on the thickness of your sheetrock. 1 /2 in (1.3 cm) holding tab 5 /8 in (1.6 cm) holding tab 1 final securing tab 2.
3.) Attach FAN to ceiling joists with BRACKETS using ROUNDHEAD WOOD SCREWS, then install the sheetrock for your ceiling. conduit ducting SHORT BRACKET (can be cut down) FAN framing joist framing joist SHORT BRACKET LONG BRACKET ROUNDHEAD WOOD SCREW Qty:6 (use 2 per bracket) /2" x #6 BRACKET SECURING SCREW Qty:3 1 4.) Attach conduit with wiring to FAN. FAN DAMPER conduit framing joist 5.) Attach DAMPER to ducting.
WARNING: Disconnect the AC power before any work is done to any part of the circuit ReVent is connected to. If you do not understand this warning, seek the services of a qualified licensed electrician. WARNING: Copper to copper only. Do not use aluminum wire. WARNING: Follow all local electrical and safety codes, and NEC (National Electrical Codes). CAUTION: If your house wires do not match these colors, determine what each house wire represents before connecting.
SWITCHES NOT INCLUDED, MUST BE PURCHASED SEPARATELY Always follow all safety instructions included with the switch you purchase. Do not exceed maximum electrical ratings. ReVent fan fan light white ground white black black fan switch (purchased separately) light switch (purchased separately) black black 120V line AC 8.) Once connected, reattach the electrical enclosure.
9.) When sheetrock is in place, press and bend the final securing tabs flat against ceiling to lock the FAN in place. final securing tabs apply even pressure to each side of securing tab sheetrock (ceiling) 10.) Align TRIM RING notch to vent (DAMPER) position. Attach TRIM RING to FAN. TRIM RING attaches to FAN body and clicks into place when secure.
11.) Connect GRILLE wire to FAN. Attach the GRILLE by squeezing the mounting springs together and inserting the springs into the spring guides in the FAN. ceiling TRIM RING FAN spring guide spring guide mounting springs GRILLE wire GRILLE Care and Cleaning WARNING: To reduce the risk of electric shock, fire, or injury to persons, disconnect or turn off the breaker and lock the power supply at the panel to prevent the power from being turned on before servicing or cleaning the unit. 1.
Frequently Asked Questions Q: How do I clean my FAN? A: It’s important to clean the GRILLE cover from time to time. Dust particles can build up on the GRILLE. See PAGE 19 for care and cleaning instructions. Q: What is CFM? A: CFM is a measurement of air movement (cubic feet per minute). The higher the CFM, the more air movement. Q: What is a Sone? A: Sone is the rating used to describe the sound level. The lower the Sone the quieter the fan.
3-Year Limited Warranty GTR Technologies Inc. (GTR) warrants to the original purchaser of its products that such products will be free from defects in materials and workmanship for a period of three years from the date of original purchase. There are no other warranties, express or implied, including but not limited to, implied warranties of merchantability or fitness for a particular purpose.