User Manual

14
Figure 1Main Burners
Burner/
Venturi Tube
LP Gas
Valve with
Orice
LP Gas
Connection
Figure 2: Side Burner
LP Gas
Connection
Valve Soft Pipe
Connection
LP Gas
Valve with
Orice
Burner/
Venturi
Tube
Figure 3
Figure 4
X
X
X
X
X
Figure 5
Lighting
Rod
Match
Operating Instructions
Checking for Leaks
Burner Connections
1. Make sure the regulator hose and valve connections are securely fastened to the burner and the
tank.
2. Visually check the connection between the burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the orifice.
W WARNING: Failure to inspect this connection or follow these instructions
could cause a fire or an explosion which can cause death, serious bodily
injury or damage to property.
4. Please refer to diagram for proper installation (Figure 1).
5. If the burner/venturi tube does not rest flush to the orifice, as shown.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three
parts water.
2. Make sure control knobs are in the “ OFF” position (Figure 3).
3. Connect LP gas tank per “Installing LP Gas Tank” section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt bottle, at all “X” locations (Figures 1, 2 and 4).
a. If any bubbles appear, turn LP gas tank valve to “CLOSED,” reconnect and re-test.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve to “CLOSED” and
disconnect LP gas tank, per “Disconnecting LP Gas Tank” section.
c. If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED,” wipe away solution
and proceed.
Operating Main Burners
First Use
1. Make sure all labels, packaging and protective films have been removed from the grill.
2. Remove manufacturing oils before cooking on this grill for the first time by operating
the grill for at least 15 minutes on
(HIGH) with the lid closed. This will “heat clean” the
internal parts and dissipate odors.
Lighting
W CAUTION: Keep outdoor gas cooking appliance area clear and free from
combustible materials, gasoline and other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may cause an
explosion.
1. Open lid.
2. Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the burner/
venturi tube. A clogged burner tube can lead to a fire.
3. All control knobs must be in the “ OFF” position (Figure 3).
4. Connect LP gas tank per “Installing LP Gas Tank” section.
5. Turn LP gas tank valve to “OPEN.”
6. Push and turn control knob to
(HIGH). the burner should light. Repeat up to three times.
7. If ignition does not occur in 5 seconds, turn burner control knob “ OFF,” wait 5 minutes, and
repeat lighting procedure.
8. If igniter does not light burner, use a lit match secured with the lighting rod (included with grill) to
light burners. Access the burners through the cooking grid and heat plates. Position lit match near
side of burner (Figure 5).
Important: Always use the lighting rod (included) when lighting burners with a match.
9. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height
matches illustration (Figure 6).
Note: Each burner lights independently - repeat steps 5-9 for the other burners.