BumpTag User Settings
Unlike BumpTag Factory Ratings, the BumpTag User Settings fields can be changed as often as you like,
however you cannot specify any values which would exceed or violate any of the Factory Ratings values.
BumpTag User Setttings contain the following fields:
Accurate Charge Rate: (default is lesser of 1.0C or 33% of Rated Max Charge C)
Normal Charge Rate: (default is lesser of 2.0C or 50% of Rated Max Charge C)
Fast Charge Rate: (default is lesser of 3.0C or Rated Max Charge C)
Discharge Rate: (default is 1.0C)
Accurate Charge Termination Voltage: (default is Rated Max Cell Volts)
Normal Charge Termination Voltage: (default is Rated Max Cell Volts)
Fast Charge Termination Voltage: (default is Rated Max Cell Volts)
Discharge Termination Voltage: (default is Rated Min Cell Volts)
Storage Charge Termination Voltage: only applies to Lithium chemistries
Default Operation: operation to selected by default when tag is bumped (default is Accurate)
Use Balance Leads: enable/disable the use of balance leads on Lithium packs (default is
enabled, can only be disabled for 1S-2S Lithium)
Trickle Rate: trickle charge rate, in C (only applies to NiXX and Pb batteries)
Trickle Timeout: trickle timeout in minutes (only applies to NiXX and Pb batteries)
Trickle After Peak Charge: checkbox to enable trickle after peak (only for NiXX and Pb)
Upload History: battery history should be uploaded for this pack (enabled by default)
Charge Counter: counts number of charge cycles on the battery (default is 0 adjust this up if
battery is used and already has some cycles)
Battery ID: Optional user-specified ID number for this pack (default is hash of NFC ID)
Fuel Table: the table of cell voltage vs fuel level (default is chemistry-specific)