REVBC-100-C1-US Revolectrix BUMP Control Unit Manual

33
Copying BumpTags
The BumpTag Copy operation will let you make an exact copy of another BumpTag (except for the
unique ID and charge counter fields). The Copy command can be used for 2 different purposes:
1. Programming a new BumpTag using Copy
If the target BumpTag is new (un-programmed), then the entire contents of the source BumpTag
(both Ratings and Settings) will be programmed into the new BumpTag. Use this to quickly setup new
batteries which are identical to some you already have.
2. Copying user Settings between BumpTags
If the target BumpTag is programmed and the Ratings fields all match exactly, then the Copy can be
used to copy user Settings to other BumpTags. Use this to quickly change Settings for a particular
type of battery just change the Settings on one battery, then select Copy and bump the rest of the
batteries of the same type. Now they will all have the exact same Settings. If the Ratings of the target
do not exactly match the source, the Copy will fail and error message will be displayed.
After pressing Copy, the battery operation screen will open and you simply bump as many target
BumpTags as you need to setup, one after the other. Once all BumpTags are written, press Cancel to
return to the main Status Screen.
NOTE: The Measured values will be copied in addition to the Settings values
this includes the Fuel Table.