REVLC06S40A-SPA-MC Revolectrix PowerLab 6 Manual

76
NiMH, NiCd and Lead Acid factory presets
NiCd Fast Charge with Trickle
Basic NiCd Fast Charge with Delta Peak Cutoff and Trickle Charge. Requires manual
charge rate setting of between 10 mA and 20A, with default value of 1A. Can charge
from 1 to 21 cell packs. Fallback default setting is 8mV. Trickle charge rate is 1/20C of
the charge rate setting. Charge will timeout in 4 hrs if peak is not reached. Trickle charge
timeout is set for 1 Day. This preset is for constant current charging applications only. Do
not use this for Li, Pb, or other chemistries. Other defaults: discharge rate set-ting is 1A,
discharge voltage 1V/cell.
NiMH Fast Charge with Trickle
Basic NiMH Fast Charge with Delta Peak Cutoff and Trickle Charge. Requires manual
charge rate setting of between 10 mA and 20A, with default value of 1A. Can charge
from 1 to 21 cell packs. Fallback default setting is 5mV. Trickle charge rate is 1/20C of
the charge rate setting. Charge will timeout in 4 hrs if peak is not reached. Trickle charge
timeout is set for 1 Day. This preset is for constant current charging applications only. Do
not use this for Li, Pb, or other chemistries. Other defaults: discharge rate set-ting is 1A,
discharge voltage 1V/cell.
NiCd/NiMH 24 Hr Trickle Charge
Basic NiCd or NiMH 24 Hour Trickle Charge preset. Requires manual charge rate setting
of between 10 mA and 500 mA with default value of 100 mA. Can charge from 1 to 21
cell packs. Trickle charge timeout is set for 1 Day.
Lead 12V SLA or Gel Cell
Basic Pb (Lead) preset for charging 12V SLA or Gel Cell batteries. Requires manual
charge rate setting of between 10 mA and 40A, with default value of 7A. Charges 12V
battery only. If you require a 24V charge, this preset is available in the library and can be
copied into the user bank (see manual for instructions). Charge will timeout in 16 hours
even if end charge voltage setting of 2.33V/cell (default) is not achieved.