Operation Guide

2 INSTALLATION GUIDE
2.4.3 Connecting the Battery Sensor
Wire the Battery Sensor as shown in Figure 2.4.1.1 ensuring that the Battery Positive
Lead connects to the house battery positive terminal. This lead measures voltage and
temperature at the battery. The “BNEG” stud connects to the House Battery negative
terminal and the “GND” stud connects to the vehicle common ground point. Connect the
CANBus Connection cable to either of the main unit CANBus interfaces.
Figure 2.4.3.1 - Battery Sensor connections
to Vehicle
Common
Ground
to House Battery
Positive Terminal
to House Battery
Negative Terminal
to CANBus
Interface
CAN Bus
Connection
2.4.4 Wiring the Main Unit
Refer to Figure 2.4.1 for required connections and to Figure 2.4.2 typical setup.
Ground
1
3
5
6
Solar Input
AC Mains Input
DC Input
Battery Output
4
2
Load Disconnect
Ignition Trigger
CANBus Interface
AC
MAINS
CANBus Interface
Figure 2.4.4.1 - Required connections.
NOTE: If a longer Remote Monitor cable is required, a replacement CAT5 patch cable
may be used, up to a length of 10m.
19