Product Manual

31
NL FR DE ES SE IT PT
EN NL FR DE ES SE IT PT
67. Temperature unit
CELC Displays the temperature in °C.
FAHR Displays the temperature in °F.
Default Range
CELC CELC/FAHR
_______________________________________________________________
68. Temperature coefficient
This is the percentage the battery capacity changes with temperature, when temperature
decreases to less than 2C (above 20°C the influence of temperature on capacity is
relatively low and is not taken into account). The unit of this value is “%cap/°C” or percent
capacity per degree Celsius. The typical value (below 20°C) is 1%cap/°C for lead acid
batteries, and 0,5%cap/°C for Lithium Iron Phosphate batteries.
Default Range Step size
0%cap/°C 0 – 2%cap/°C 0,1%cap/°C
_______________________________________________________________
69. Aux input
Sets the function of the auxiliary input:
START Auxiliary voltage, e.g. a starter battery.
MID Mid-point voltage.
TEMP Battery temperature.
The cable with integrated temperature sensor has to be purchased separately (part no:
ASS000100000). This temperature sensor is not interchangeable with other Victron
temperature sensors, as provided with Multis or battery chargers.
_______________________________________________________________
70. Start synchronized
When ON, the BMV will consider itself synchronized when powered-up, resulting in a state-
of-charge of 100%. If set to OFF, the BMV will consider it unsynchronized when powered-
up, resulting in a state-of-charge that is unknown until the first actual synchronization.
Default Range
ON OFF/ON
_______________________________________________________________
71. Bluetooth mode (BMV712 only)
Determines whether to enable Bluetooth. If turned OFF using the VictronConnect app, the
Bluetooth functionality is not disabled until disconnected from the BMV. Note that this
setting is only available when the firmware of the on-board Bluetooth module supports this
functionality.
Default Range
ON OFF/ON