- Table 2
- If the heat anticipator is set too high, the furnace may delay activation of a heating cycle for too long. If the heat anticipator is set too low, the furnace may cycle too frequently. Either condition may not provide optimal comfort to the homeowner.
- ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
- ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
All installations and services must be performed by qualified service personnel.
12
B. BASE INSTALLATION
1. Combustible Floor Base Model: V70-BASE
Use the base bottom panel as a template to mark floor opening locations (see
Figure 2). Cut a square opening in the floor for the supply air connector duct. Cut
the opening 1-inch larger than the square template opening. (duct requires 1-inch
clearance to combustible floor).
Figure 2.
Figure 3.
After cutting openings in the floor, place the bottom panel in position. Mark the
square opening location on the distribution duct at the connection point of the