VMA/VMC Installation Manual
Table Of Contents
- FOR YOUR SAFETY
- WHAT TO DO IF YOU SMELL GAS
- Table 2
- If the heat anticipator is set too high, the furnace may delay activation of a heating cycle for too long. If the heat anticipator is set too low, the furnace may cycle too frequently. Either condition may not provide optimal comfort to the homeowner.
- ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
- ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
All installations and services must be performed by qualified service personnel.
44
3 flashes, then pause pressure switch stuck open
4 flashes, then pause open high limit switch
6 flashes, then pause 115 volt AC power reversed
7 flashes, then pause low flame sense signal
8 flashes, then pause check ignitor or improper grounding
Continuous flashing Flame has been sensed when
(no pause) no flame should be present
(no call for heat)
The LED will also flash once at power-up.
: Power must be disconnected before servicing.