VMA/VMC Installation Manual
Table Of Contents
- FOR YOUR SAFETY
- WHAT TO DO IF YOU SMELL GAS
- Table 2
- If the heat anticipator is set too high, the furnace may delay activation of a heating cycle for too long. If the heat anticipator is set too low, the furnace may cycle too frequently. Either condition may not provide optimal comfort to the homeowner.
- ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
- ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
All installations and services must be performed by qualified service personnel.
48
DOES SYSTEM RUN UNTIL
THERMOSTAT IS SATISFIED?
CHECK ALL
WIRING FOR
LOOSE CONNECTIONS.
CHECK FOR SHORT IN WIRE TO
THERMOSTAT AND CORRECT
IF NECESSARY.
DOES BURNER SHUT OFF
WHEN THERMOSTAT IS
SATISFIED?
No
DOES THE CIRCULATING
AIR BLOWER TURN OFF
AFTER THERMOSTAT IS
SATISFIED WITHIN
120 SECONDS?
No No
Yes
Yes
Yes
Yes
Yes
IS LED LIGHT
ON INTEGRATED
CONTROL FLASHING?