MG2S Spec Sheet

5
BLOWER PERFORMANCE - Front Return
MODEL NUMBER
MOTOR SWITCH
SETTINGS
(0 =OFF,1 =ON)
COOLING HEATING
EXTERNAL STATIC PRESSURE (IN.W.C.) EXTERNAL STATIC PRESSURE (IN.W.C.)
0.2 0.3 0.4 0.5 0.2 0.3 0.4 0.5
1/5 2/6 3/7 4/8 CFM CFM CFM CFM CFM RISE CFM RISE CFM RISE CFM RISE
MG2S-045F*
0 0 0 0 913 868 841 795 913 44 868 46 841 48 795 50
1 0 0 0 965 944 886 848 965 41 944 42 886 45 848 47
0 1 0 0 1037 1000 973 933 1037 39 1000 40 973 41 933 43
1 1 0 0 1112 1079 1047 1012 1112 36 1079 37 1047 38 1012 40
0 0 1 0 1185 1155 1118 1082 1185 34 1155 35 1118 36 1082 37
1 0 1 0 1256 1216 1180 1151 1256 32 1216 33 1180 34 1151 35
0 1 1 0 1289 1258 1222 1186 1289 31 1258 32 1222 33 1186 34
1 1 1 0 1354 1319 1283 1247 1354 30 1319 30 1283 31 1247 32
0 0 0 1 1396 1366 1331 1299
1 0 0 1 1442 1411 1379 1351
0 1 0 1 1485 1451 1421 1388
1 1 0 1 1510 1473 1446 1416
0 0 1 1 1550 1517 1494 1460
1 0 1 1 1588 1561 1530 1503
0 1 1 1 1635 1606 1582 1554
1 1 1 1 1646 1612 1582 1550
MG2S-060F*
0 0 0 0 913 868 841 795 913 58 868 61 841 63 795 67
1 0 0 0 965 944 886 848 965 55 944 56 886 60 848 63
0 1 0 0 1037 1000 973 933 1037 51 1000 53 973 55 933 57
1 1 0 0 1112 1079 1047 1012 1112 48 1079 49 1047 51 1012 53
0 0 1 0 1185 1155 1118 1082 1185 45 1155 46 1118 48 1082 49
1 0 1 0 1256 1216 1180 1151 1256 42 1216 44 1180 45 1151 46
0 1 1 0 1289 1258 1222 1186 1289 41 1258 42 1222 44 1186 45
1 1 1 0 1354 1319 1283 1247 1354 39 1319 40 1283 42 1247 43
0 0 0 1 1396 1366 1331 1299
1 0 0 1 1442 1411 1379 1351
0 1 0 1 1485 1451 1421 1388
1 1 0 1 1510 1473 1446 1416
0 0 1 1 1550 1517 1494 1460
1 0 1 1 1588 1561 1530 1503
0 1 1 1 1635 1606 1582 1554
1 1 1 1 1646 1612 1582 1550
MG2S-072F
0 0 0 0 923 884 843 798 923 69 884 72 843 76 798 80
1 0 0 0 964 922 886 843 964 66 922 69 886 72 843 76
0 1 0 0 1052 1017 977 938 1052 61 1017 63 977 66 938 68
1 1 0 0 1117 1088 1049 1017 1117 57 1088 59 1049 61 1017 63
0 0 1 0 1196 1163 1131 1092 1196 54 1163 55 1131 57 1092 59
1 0 1 0 1258 1219 1190 1151 1258 51 1219 53 1190 54 1151 56
0 1 1 0 1283 1248 1213 1177 1283 50 1248 51 1213 53 1177 54
1 1 1 0 1335 1299 1268 1234 1335 48 1299 49 1268 50 1234 52
0 0 0 1 1389 1356 1322 1292 1389 46 1356 47 1322 48 1292 50
1 0 0 1 1442 1406 1374 1340 1442 44 1406 46 1374 47 1340 48
0 1 0 1 1480 1446 1415 1382 1480 43 1446 44 1415 45 1382 46
1 1 0 1 1506 1475 1442 1410 1506 42 1475 43 1442 44 1410 45
0 0 1 1 1542 1507 1474 1443 1542 42 1507 42 1474 43 1443 44
1 0 1 1 1583 1554 1518 1488 1583 40 1554 41 1518 42 1488 43
0 1 1 1 1630 1601 1563 1530 1630 39 1601 40 1563 41 1530 42
1 1 1 1 1633 1599 1564 1529
Greyed out blower speeds do not meet FER efficiency requirements and should not be used.