MG2S Brochure

www.stylecrestinc.com | 800.945.4440
SKU
AHRI
Cert. #
Low-fire
Input
Low-fire
Capacity
High-Fire
Input
High-Fire
Capacity
Ship
L
Ship
W
Ship
H
Ship
Wt.
Orifice
1
MOP
NG LP Qty
MG2S-045F 203049789 29 MBH 27.8 MBH 45 MBH 43.2 MBH 26 ½" 21 ½" 78" 179# 49 1.1mm 3 15A
MG2S-060F 203049796 39 MBH 37.4 MBH 60 MBH 57.6 MBH 26 ½" 21 ½" 78" 179# 45 1.25mm 3 15A
MG2S-072F 203049801 47 MBH 45.1 MBH 72 MBH 69.1 MBH 26 ½" 21 ½" 78" 186# 47 1.2mm 4 15A
MG2S-045T
2
203049794 29 MBH 27.8 MBH 45 MBH 43.2 MBH 26 ½" 21 ½" 78" 179# 49 1.1mm 3 15A
MG2S-060T
2
203049799 39 MBH 37.4 MBH 60 MBH 57.6 MBH 26 ½" 21 ½" 78" 179# 45 1.25mm 3 15A
MG2S-072T
2
203049803 47 MBH 45.1 MBH 72 MBH 69.1 MBH 26 ½" 21 ½" 78" 186# 47 1.2mm 4 15A
Direct Vent, Dual-Pipe Specifications
MG2S 96% AFUE 2-Stage MH Gas Furnaces
©Style Crest®, Inc. 2019 | Product availability and specifications are subject to change without notice | 4/15/2019 | MG2S 96% 2-Stage MH Gas Furnaces | Sell Sheet, RVL-0067
Accepted Pipe Material
ANSI/ASTM
Standard
Schedule 40PVC D1785
PVC-DWV D2665
SDR-21 & SDR-26 D2241
ABS-DWV D2661
Schedule 40ABS F628
Foam/Cellular Core PVC F891
PolyPro® by Duravent ULC-S636
Item SKU Item Description
901988A Duct Connector, 11¼"x13½"x2"H, EA
(12/Ctn)
901989A Duct Connector, 11¼"x13½"x4¼"H, EA (6/Ctn)
901990A Duct Connector, 11¼"x13½"x6¼"H, EA (6/Ctn)
901991A Duct Connector, 11¼"x13½"x8¼"H, EA (4/Ctn)
901992A Duct Connector, 11¼"x13½"x10¼"H, EA (3/Ctn)
901993A Duct Connector, 11¼"x13½"x12¼"H, EA (3/Ctn)
Application Accessories
1) Orifice required will vary with altitude; consult the unit installation instructions for correct orifice selection for your application and altitude.
2) These items are available as drop-ship only (not stocked), where a non-cancellable order mininum and longer lead-time may apply.
24 ⁄"
19 ⁄"
76”H
with 20”H
Coil Box
Item SKU Item Description
901083 Backflow Damper, 1-Blade, For Pkgd AC
902095 BF Damper, 3-Blade, Pkgd AC, Low Profile
904953 3ӯ Pipe, Concentric Vent Term. Kit, US/CA
904106 2-Pipe, Vent Transition Kit (old RJ opening)
901987A Duct Connector, 11¼"x13½"x⅞"H, EA
(12/Ctn)
Venting Notes:
Above table applies from sea level to 2,000ft. For higher elevations,
decrease vent pipe lengths by 8% per 1,000ft of additional altitude.
Subtract 3.5ft for each additional 3"-90° elbow.
Subtract 2.5ft for each additional 2"-90° elbow.
Two 45° elbows are equivalent to one 90° elbow.
1-short radius elbow is equivalent to 2-long radius elbows.
Do not include termination elbows in vent length calculation.
Only listed pipe materials are approved for use with MG2S furnaces.
904106
Max Equivalent Pipe Length
Input 3ӯ In/Outlet 2ӯ In/Outlet
45 MBH 60 ft 30 ft
60 MBH 60 ft 30 ft
72 MBH 60 ft 30 ft
902095
901987A
901083
904952