MG3P Technical Specs
4
SPECIFICATIONS
Note: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efciency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
MG3P MODEL NUMBERS: -054U1AAB1 -072U1AAC1 -090U1AAC1 -108U1AAD1
Input - Btuh (a) 54,000 72,000 90,000 108,000
Heating Capacity - Btuh 50,000 66,000 83,000 99,000
AFUE 92.0 92.0 92.0 92.0
Blower D x W 11 x 8 10 x 10 11 x 10 11 x 10
Motor H.P. - Speed - Type 3/4 - 5 - ECM 3/4 - 5 - ECM 1 - 5 - ECM 1 - 5 - ECM
Motor FLA 8.8 8.8 11.5 11.5
Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5
Temperature Rise Range - ºF 30-60 35-65 35-65 40-70
Shipping Weights 120lbs 130lbs 135lbs 155lbs
MODEL IDENTIFICATION CODE
Gas Furnace
Efficiency (AFUE)
E = 80.0%
H = 83.0%
J = 84.5%
P = 92.0%
R = 95.0%
S = 96.0%
M
3
072
U
1
Input Heating Capacity
(BTU)
045 = 45,000
060 = 60,000
072 = 72,000
Series
Manufactured Housing
P
F = Front Return Downow
T = Top Return Downow
U = Upow
A = 120V, 1 Phase, 60 Hz
G
A = No Evap Coil Cabinet
B = Cabinet ts 18' nominal coil heights
C = Cabint ts 24" nominal coil heights or
smaller
A
A
1 = Single Stage
2 = Two Stage
1
Revision
C
Cabinet Width
M = Manufactured Housing
B = 17.5"
C = 21.0"
D = 24.5"