Konfiguration M217 R45of of M217 Wall Display Unit E 2.
Re:control M217 Wall display M217 General Installation advice & Multiroom Planer Safety Guidelines 2 2 2 3 Connection schematic M217 4 GIRA M217 5-6 Feller EDIZIOdue 4217.
Re:control M217 Wall display M217 Installation height Please read these instruction through completely and carefully before setting the unit up. The ideal installation height for the M217 display unit is approx. 150 cm / 59 inch (centre of display). This results in a good reading angle and comfortable operation of the display unit/ operating unit combination for smaller people as well. The operating unit should be attached below the display unit.
Re:control M217 Danger warning Installation Improper mounting of this device in an environment with low-voltage products (230 V AC) can cause serious health problems or damage to property. This product is intended for connection to extra low voltage circuits and may never be connected to low voltage (230 V AC). The device may only be mounted, connected and removed by qualified personnel.
Re:control M217 Connection Revox recommends using a 4-lead telephone cable (1 x 4 x 0.5 mm²) with an RJ11 plug (6P4C modular) for connection to the Revox multiroom system or Revox secondary M219 room amplifier. Maximum cable length: 100 m Max. cable resistance: 0.1 Ω /m M217 The cabling for the combination of the 217 display and the 218 keypad should be done as shown in the drawing. With the combination solution, the 218 keypad only has a connection to the 217 display.
M217 GIRA M217 The company Gira offers the M217 wall display, which is compatible with the REVOX Multiroom system. The M217 display unit shows the most important functions and information from a Revox Multiroom System in the primary and secondary rooms. Combination M217 + M218 (optional) Ideally, the M217 display unit is combined with the M218 operating unit, which enables easy and logical operation of the music system.
M217 Installation procedure You should avoid applying any pressure to the display during or after installation. 1. 2. 3. Screw the mounting fixture (4) onto the recessed or surface mounted box. Strip the insulation off the installation cable and feed it through the mounting fixture (4). Connect the cable to the Phoenix screwed terminal block. 4. 5. 6.
M217 Feller EDIZIOdue 4217.M Advice The Swiss company Feller offers the 4217.M wall display from their EDIZIOdue series, which is compatible with the REVOX Multiroom system. The IR receiver must be activated if the wall display is used on its own without a 4218.M keypad. In this case, the DIL switch 1 on the back of the wall display must be switched on (IR on). Revox recommends the use of ITPlus® RJ45 sockets for the interface to the main system (Re:system) and/ or the M219 side room amplifier.
M217 Installation procedure You should avoid applying any pressure to the display during or after installation. 1) Install the mounting fixture (5) with the fixing plate (4) onto the recessed box or the surface mounted box on the wall. 2) Strip the insulation off the U72 installation cable and feed it through the mouting fixture (5). 3) Connect the cable to screwed terminal block. the 1 3 2 4) Connect the terminal block with the print connector on the back of the operator panel (1).
M217 Jung / Merten M217 Available designs Revox offers the M217 for the Central European market in different designs from the Jung and Merten companies. You can see from the list on the right, which designs are available from each of the manufacturers. JUNG CD 500 / universal JUNG CD plus JUNG LS990 / LS plus Colours: Alpine white Other colours and designs are available on request at additional cost, if applicable.
M217 Installation procedure You should avoid applying any pressure to the display during or after installation. 1) Screw the mounting fixture (4) onto the recessed or surface mounted box. 2) Strip the insulation off the installation cable and feed it through the mounting fixture (4). 5) Locate the operator panel (1) with its frame (3) onto the mounting fixture (4), so that the clip connectors (2) on the panel (1) line up with the cut-out (5) in the mounting fixture (4). 6) 3) Connect Phoenix block.
Re:control M217 Connection plan M217 Setup and operation The wall display must be connected to a Revox Re:system device or a Revox M219 Additional room amplifier for setup. Technical data Advice Information about and support for setup and operation can be found in the Revox manuals. Protection IP20 in accordance with IEC529; Dry installation Build-in depth 20 mm Temperatures Operation: -5°C to +45°C Storage: -25°C to +70°C Cable Installation cable U72 ABG 1 x 4 x 0.
Konfiguration M217 M217 Configuration Important The basic settings for the M217 are made with the four DIL switches on the back of the unit. Use a small screwdriver or the point of a ballpoint pen to set the switches. The addressing of the M217 and the M219 must be setup correctly to ensure error free operation. The configuration must be done while the unit is removed from the power, otherwise any changes made will not be effective. Please note: ON is with the switch in the upper position.
Re:control M217 M217 Address setting Connection to a Re:system device (M10, M100, M51) If the M217 is connected directly to a Re:system device (M-Link) the address setting is not significant. The M217 will be recognises automatically. Connection to the M219 side room amplifier If, on the other hand, the M217 is to be connected to a M219 side room amplifier, address setting is very important. The M217 address defines which M219 should be communicated with.
Konfiguration M217 A/B Operation: 2 displays control one side room amplifier The Multiroom system from Revox allows one M219 to be controlled by two M217s, the so-called A/B operation. In this way, for example, an M217 could be installed on each side of the bed. In A/B operation, the second M217 has the same address set through DIL switches 3 & 4 as the first M217, but with DIL switch 2 activated. In this way, the first M217 works in A and the second in B operation.
Re:control M217 Operating with Softkeys MAIN MENU Softkeys are used for control so that the M217 display remains clear to use, in spite of the large number of options available. The main menu shows you clearly detailed information in the M217 display. The control is effected either by the connected wall control unit M218 or by a IR remote control. A Softkey is a key that can be assigned different functions depending on which menu is currently active.
Operation M217 Setting the display contrast Setting the time in the side room The contrast of the display is adjusted by Revox to an optimal reading angle. The time can also be set from a side room, assuming that an M217 Wallmounted display is being used. Depending upon installation position it can occur however that a stronger or weaker contrast attitude supplies the better reading off result. This contrast attitude can later be made with the help of the two marked softkeys in the Standby mode.
Re:control M217 Timer programming TIMER MENU The concept of the programming is as follows: The Timer is the control centre of the Multiroom system. Using the Timer, you can set a wakeup alarm for specific days or lull yourself off to sleep with the Sleep function. timer Firstly, you select one of the four Timers and then assign it the required properties. The following figure shows the inside Timer display field with the corresponding assignments.
Operation M217 Timer selection The Select options Select Select The properties of the individual Timers can be set with the Select softkey: c Switching time d Weekday e Volume f Select timer source g (Select tuner station) Timer 1 has been selected in the above example. The individual Timers can be selected with the Timer soft keys. There are a total of 4 independent Timers to choose from. If you reach Timer 4, pressing the softkey again brings you back to Timer 1.
Re:control M217 Only switch on or off c Switching times Select Sometimes, it is useful just to switch the music equipment on at a specific time and switch it off manually, or vice-versa. Once you have selected a Timer, you can define the switch on/off times with the Select softkey. The first time the Select key is pressed, the first counter pair appears in square brackets. In order to make only one timepoint active, you select the display **:** when setting the hours value.
Operation M217 d Weekday Select Once you have defined the switch-on and switch-off timepoints, by pressing the Select key again, you can reach the next stage where you define the weekdays when the timer is to be activated. M T W T F S S SS MTWTF MTWTFS MTWTFSS Timer weekday examples: As well as the individual days from Monday to Sunday, you can also select from specific day groups.
Re:control M217 f Select timer source e Volume Select Select After selecting the weekday(s), the next time you press Select, you will be prompted to set the volume level that should be used. The Multiroom module timer offers your three sources that can be activated when the timer kicks in. These are Tuner, DVD/CD and Aux/Server. Please note Using the softkeys, you set the volume level between 1 (very low) and 9 (very loud).
Operation M217 g Select Tuner station 1 Select Assuming that you have selected Tuner as your source, a further press of Select will bring you to the point where you can select the station you want to listen to. If you have selected DVD/CD or Aux/Server on the other hand, you will return to the Switching times selection level. 2 3 Ç Remote menu Re:system The third option in the Remote menu is to deactivate a source (Fig e).
Re:control M217 Activate Timer Timer status & time display As default, the individual Timers are deactivated. As soon as the switching times of a Timer are modified, the corresponding Timer is activated automatically and the small bell symbol in the top line of the display changes from showing c to d If one or more Timers are activated, two bell symbols are displayed when the M217 is in standby mode. Both bell symbols only disappear once all Timers have been deactivated.
Operation M217 Nested events Sleep function Sleep Through the Timer programming, you can create nested events. Nested events occur when two different events address the same source and at the same time. Using the Sleep function, you can define a length of time after which the Re:system device or the M219 will automatically switch off. By repeatedly pressing the Sleep softkey, you can step through a loop in 15 minute steps, to set the required time period.
Re:control M217 Guarantee Care The guarantee period is 24 months from the date of purchase. Clean the user surface, including display and keys as well as the frame, with a damp cloth. Apply a few drops of non-abrasive, washing-up liquid to the damp cloth to remove any stubborn marks. Your dealer should be your first contact if you need service. If he can't give you the help you need, send the M217 Display without any accessories to your national Sales Office.
Appendix M217 Technical Data Connections Max. cable lengths: VCC: + 8 to 20 V A: Bus-communication B: Bus-communication GND: Ground / screening 100m M217 - Re:connect M219 100m M217 - Re:system M10, M100, M51 30 m M217 - Re:control M218 keypad Power consumption: at the M51: 30 - 50 mA at the M219: 50 - 100 mA Operating conditions: (off –max. brightness) (off –max. brightness) (Humidity class acc. to DIN 40040), "+10°... +40°C" Errors and technical modifications excepted.
Re:control M217 27
Appendix M217 M217 Display Operating instructions / Part no.: 10.30.