Technical data

Konfiguration M217
12
M217 Configuration
The basic settings for the M217 are
made with the four DIL switches on
the back of the unit. Use a small
screwdriver or the point of a ballpoint
pen to set the switches.
Important
The addressing of the M217 and the
M219 must be setup correctly to
ensure error free operation. The
configuration must be done while the
unit is removed from the power,
otherwise any changes made will not
be effective.
NO Function Factory setting
1 M217 IR eye on/off On
2 A/ B operation Off
3 M217 Address Off
4 M217 Address Off
Please note:
ON
is with the
switch in the upper
position
.
M217 Infrared receiver on/off
If you are combining the M217 display with the M218 remote control, which also
has an IR receiver, one of the two IR receivers must be disabled, as otherwise IR
commands will be carried out double.
In some cases, e.g. in buildings with glass internal walls, it can be advantageous
to switch of the IR receiver on the M217, in order to avoid conflicts with other
devices.
The only switch that can be set during operation of the unit is DIL switch 1 for the
IR receiver.
IR Function
DIL switch
1
DIL position
IR - On On
1
IR - Off Off
1
With the M217, the integrated IR receiver is located in the lower right-hand
display field.