Replacement Parts Guide

Form P-PILOTS, Page 4
FIGURE 10 - Vertical Spark Pilot for
Models RCG 2 - 5 ton with Vertical Pilot
Protective Boot,
P/N 112648
Effective with replacement pilots
purchased 9/91, these parts are re-
quired (in the kit or separately) when
the replacement pilot is for heater
Models listed in FIGURES 6, 9 and
10 equipped with a Model G60 or
G67BG-NG-2 ignition controller.
(Note: These parts are not required
when the ignition controller is a
Model G67BG-5 or G770NGC-4.)
Crimp-on, 90° Rajah
Terminal Connector,
P/N 112647
1. Identify the ignitor wire attached to the
pilot electrode. Slip the 90° protective
boot on to the wire, as illustrated è.
2. On the "open" leg of the 90° crimp-on
terminal (P/N 112647), locate a flat,
triangular spike tab punched in the
metal. With the tip of a small, straight
screwdriver, force the spike tab toward
the inside of the connector. Straighten
the tab to a vertical position.
3. Insert the ignitor wire into that same
connector leg (just to the 90° bend) and
push the wire onto the protruding spike
tab, making sure that the tab penetrates
the insulation. (Do not strip the ignitor
wire.) Using a crimping tool or pliers,
squeeze the sides of the terminal to
form a "C" shape. The ignitor wire
should now be firmly held by the
terminal.
FIGURE 11 - Pilot Systems used
on Direct-Fired Models RDF/
ADF/ADFH/DFA/DV
Instructions for connecting ignitor lead on replacement spark pilots to Model G60 and G67 ignition
controllers (applies to Pilot Kits in FIGURES 6, 9, and 10):
www.RezSpec.com; 800-695-1901
©2010 Thomas & Betts, All rights reserved.
Trademark Note: Reznor
®
is registered in at least the United States.
11/10 P-PILOTS (Version .2)
4. Slide the protective boot over the
terminal. Holding the boot, attach the 90
o
Rajah terminal to the ignitor lead Rajah
connector on the Model G60 or G67BG/
NG-2 ignition controller.
*P/N 135435 is a replace-
ment flame sensor only kit
for ADF/ADFH units manu-
factured prior to 11/94.
Hot Surface Ignition Kits below include all components needed to change RDF units from a
spark pilot system with either a flame probe or ultraviolet sensor to hot surface ignition
- for an RDF unit with a 200VA Transformer - P/N 146268
- for a 115V RDF unit with an 80VA transformer - P/N 146318
- for a 208V RDF unit with an 80VA transformer - P/N 146319
- for a 240V, 480V, or 575V RDF unit with an 80VA transformer - P/N 146320
NOTE: Model, Serial No., and
Wiring Diagram No. MUST be
provided when ordering
these kits.
2
3
4
5
6
1
*See instructions below.
Step 1 - Slip
Boot over
Install boot
and terminal
on ignitor wire
Step 2 & 3 - Attach
90°, Crimp-on
Step 4 - Attach to
Ignition Controller
Replacement Natural Gas - P/N 110867
Pilot Kits Propane Gas - P/N 110868
Code
P/N
Component Description
1
47484
Natural Gas Pilot with orifice, high tension lead and built-in flame probe; less
pilot tubing, less sensor lead (Baso #J993HHW6221)
47485
Propane Gas Pilot with orifice, high tension lead and built-in flame probe; less
pilot tubing, less sensor lead (Baso #J993HHW4211)
2
44048
Natural Gas Orifice only, #6221
42089
Propane Gas Orifice only, #4211
3
44183
Sensor lead, 38" lg
4
7671
Pilot tubing 26" lg
9664
Nut with breakaway ferrule (2 required when replacing pilot tubing)
5*
112647
Crimp-on, 90
o
Rajah terminal connector
6*
112648
90
o
Boot Terminal Protector
Replacement w/Flame Probe - P/N 110869
(Includes Codes 1, 2, 3)
RDF with spark pilot
Pilot Kits w/Ultraviolet Sensor - P/N 110918
(Includes Codes
1, 2, 4)
RDF with spark pilot
w/Hot Surface Ignition - P/N 120048
(Includes
Codes 5, 6, 7, and 8)
ADF/DFA/RDF/DV wit
h
hot surface ignition
Code
P/N
Component Description
Applies to
1
Pilot Supply Connection including: (1) brass elbow,
P/N 93388
; (3) connectors,
P/N 95188
; (1) long nut,
P/N 95189
RDF Models
2
87936
Spark Plug, 27750-1-31, Maxon #18075
with a spark pilot
3
87937
Flame Probe, Auburn AA67-7892-1 - Standard on
units with date code prior to ANI (9/88)
and either a probe or
ultraviolet
4
89411
Ultraviolet Minipeeper, #C7027A - Standard on units
with date code from ANI (9/88) through AVB (2/96) -
optional on prior units
flame sensor
5
122840
Pilot Plate and Tubing Assembly ADF/ADFH*; DFA;
6
134706*
Flame Sensor, J/C #Y75MK-1D DV; and RDF with
7
121865
Ignitor, Norton #401E
hot surface
8
121730
Pilot Bushing
ignition
6
5
8
7
4
3
2