Replacement Parts Guide

Form P-FAN&LIMIT, P/N 147678 R2, Page 1
Replacement Parts/Service
IMPORTANT
1. Always include complete heater model and serial number
so that any specication change can be considered for
parts shipment. It can save time and expense.
2. Check temperature setting on control being replaced.
3. We reserve the right to substitute functional replacements.
4. Specications are subject to change without notice.
APPLIES TO: Functional Replacement
Fan/Blower Controls and
Limit Controls
P-FAN&LIMIT (Version B)
Obsoletes Form P-FAN&LIMIT (Version A)
TABLE 1 - Functional
Replacement Fan/
Blower AND/OR
Limit Controls by
Heater Model Group
listed alphabetically
(applies to currently
manufactured units)
Footnotes for TABLE 1:
IMPORTANT: Always verify
temperature setting of the
original control.
A
Model B Sizes 50, 75, & 100
manufactured prior to 9/96
use limit control, P/N 45602
(180°F).
B
Models B and F with spark
pilot manufactured after
9/99 (Serial No. Date Code
AYJ) do not have an ECO
limit control.
C
P/N 209184 is a relay kit
to replace discontinued
fan control P/N 10357. Kit
includes instructions.
D
Furnace next to the blower.
E
Second furnace from the
blower
F
Third furnace from the blower.
SECTION 1
Table of Contents
SECTION 1 - Table 1, Functional Replacement Fan/Blower and/or Limit Controls for currently manufactured Models/Series 1
SECTION 2A - Table 2, Functional Replacement Fan/Blower & Limit Controls for no-longer-manufactured Models/Series .....3
SECTION 2B - Installing Replacement Fan Control on Models (C)XL, (C)EEXL, (C)XLB, and (C)EEXLB .................................... 6
SECTION 2C - Installing Functional Replacement for Discontinued Fan Control, Relay Kit P/N 63254 .......................................7
(continued on page 2)
Model Size Limit Control Fan Control
ADF All Sizes
122856 (130ºF), auto, orange
None
122858 (135ºF), manual, pink
82414 (306ºF), ECO Device
ADFH All Sizes
19080 (155ºF), auto. yellow
None
122990 (175ºF), manual, tan
82414 (306ºF), ECO Device
B
25 45602 (180ºF), auto, white
123975 (150ºF)
A
50, 75, 100
A
85449 (200ºF), auto, yellow
125-400 100799 (150ºF), auto, white
B
ECO Limit
Control for B
25-50 131449, (228ºF)
75-400 131450, (306ºF)
CAUA
150, 200
148588 (270ºF) w/60" capillary
None
Flame Rollout Limit,
112752, (225ºF)
250, 300
164792 (300ºF) w/54" capillary
Flame Rollout Limit,
121275, (275ºF)
350, 400
148588 (270ºF) w/60" capillary
Flame Rollout Limit,
112752, (225ºF)
(H)EEDU All 45602, (180°F), auto, white 147611
F
25 85449, (200ºF), auto, yellow 123974 (135ºF)
50 85449, (200ºF), auto, yellow 123976 (135ºF)
A
75, 100
A
85449, (200ºF), auto, yellow 123976 (135ºF)
125 45602, (180°F), auto, white 123976 (135ºF)
130, 165 82091, (160°F), auto, red 123976 (135ºF)
200 85449, (200°F), auto, yellow 123974 (135ºF)
250, 300, 400
45602, (180°F), auto, white 123974 (135ºF)
B
ECO Limit
Control for F
25-50 131449, (228ºF)
75-400 82414, (306ºF)
LDAP
400
Limit,
112753 (150°F), white
None
Limit,
202048 (240°F), auto, silver
800
(2) Limit,
112753 (150°F), white
(2) Limit,
202048 (240°F), auto, silver
1200
(3) Limit,
112753 (150°F), white
(3) Limit,
202048 (240°F), auto, silver
All Linear Limit w/60" Capillary, 148588 (270°F), auto
OH
95 Fan & Limit Control Assembly, P/N 123977
140, 190 Fan & Limit Control Assembly, P/N 123973
PDH/SDH/RDH
75-150 40" Capillary, Auto Reset, P/N 210854 (190°F), yellow
None175-225 60" Capillary, Auto Reset, P/N 210855 (240°F), green
250-400 60" Capillary, Auto Reset, P/N 211066 (300°F), red
PEH/REH All P/N 254754, Auto Reset, 3/4" disc None
MAPS III
RDCB, RDDB
Gas Heat
Section
100 P/N 258855 (240°F), 22" capillary, auto, white
None
150-800 P/N 148588, 60" Capillary, Auto Reset, (270°F)
1000-1600
P/N 148588, 60" Capillary, Auto Reset, (270°F)
P/N 82414, ECO, 306°F