Installation - Vertical Louvers

Form I-F/B-VL, Mfg #97925 Rev 3, Page 1
INSTALLATION FORM RZ/NA I-F/B-VL
Obsoletes Form 434/436-VL (Version A.2)
OPTION CD1 25-50 75 100 125 130 165 200 250-300 400
Vertical Louvers
Qty P/N Qty P/N Qty P/N Qty P/N Qty P/N Qty P/N Qty P/N Qty P/N Qty P/N
Option Package P/N 98500 98501 98502 136863 98503 98504 98505 98506 98507
Top and Bottom Members 2 97852 2 97853 2 97854 2 97856 2 97854 2 97856 2 97856 2 97857 2 97858
Vertical Louvers 4 95937 4 95937 4 95937 6 95937 4 95938 6 95938 6 95938 8 95938 10 95938
Screws 12 11813 12 11813 12 11813 16 11813 12 11813 16 11813 16 11813 20 11813 28 11813
WARNING: Improper installation, adjustment,
alteration, service, or maintenance can cause
property damage, injury or death. Read the
installation, operation, and maintenance
instructions thoroughly before installing or
servicing this equipment.
INSTALLATION INSTRUCTIONS
Installation should be done by a qualified agency in accordance with the
instructions on this sheet and in compliance with all codes and require-
ments of authorities having jurisdiction.
Tools Required: 5/16" Nut Driver
1. Assemble the Louvers - Assemble vertical louvers to the top and
bottom members using the sheetmetal screws provided (See Figure
1).
a. Vertical louver edges should extend beyond the front outer end of
the louver top and bottom members.
®
OPTION CD1
VERTICAL LOUVERS
APPLIES TO: Models F, FE, B, and BE
The vertical louver option packages include:
IMPORTANT NOTE: On fan models (Models F and FE), do not install vertical louvers in combination with Option CD3, Downturn Nozzle with 50
o
-90
o
Variable Air
Deflection Range (formerly identified as a 60
o
nozzle).
CAUTION: To avoid getting burned,
adjust louvers while heater is not in
operation. If louvers are adjusted
while heater is in operation, wear
protective gloves.
Figure 1 - Installing Optional
Vertical Louvers
HAZARD INTENSITY LEVELS
1. DANGER: Failure to comply will result in severe personal
injury or death and/or property damage.
2. WARNING: Failure to comply could result in severe personal
injury or death and/or property damage.
3. CAUTION: Failure to comply could result in minor personal
injury and/or property damage.
b. Stops are designed so that the right half of the louvers turn right
and the left half of the louvers turn left.
2.
If the heater is installed, for your safety, turn off the gas and
the electrical power before installing the assembled vertical
louvers.
3. Prepare Heater Front Panels (Top and Bottom) -- Holes re-
quired in the top and bottom front panels are punched at the fac-
tory. The holes in the bottom front panel have screws inserted.
Remove the factory-installed screws from the bottom front panel
(save the screws to use in attaching the louver assembly).
4. Install the Louver Assembly -- Using the sheetmetal screws, at-
tach the top member of the vertical louver assembly to the top front
panel of the heater and the bottom member of the vertical louver
assembly to the bottom front panel.
5. Adjust the horizontal and vertical louvers to provide the desired air
direction. See CAUTION below.
6. Turn on the electric and the gas. Relight by following the lighting
instructions on the heater. Check for proper operation.