Installation Manual User guide

19
IMPORTANT!
Never cut or try to shorten the heating cable.
• Ensure that the EFMA surface is at against the suboor;
• Avoid walking on the EFMA system. If you must, wear so rubber soled shoes;
• Always start unrolling EFMA at least 50mm (2”) from the walls;
• To work around stationary elements, detach a section of heating cable from the mat
and use it to cover a tight space or work around an object;
• It is important not to subject the heating cable to any mechanical strain (stretching,
radius bending under 20mm [¾”], scoring).
4.4.2 Mat Rippling
• Carefully atten the mat against the suboor to ensure it and the heating cable can
be completely embedded in the cement or other binder to be applied in the next
step;
• If the mat ripples, score the center of the rippled section and atten the edges (Fig.
4.4.2).
Fig. 4.4 2
IMPORTANT!
Never cut or score the heating cable.
Measure the cables electrical and insulation resistance and record the
readings on line 2) Aer installing the heating cable of the
measures’table.