EGEB Installation Manual 10.1 kW to 20 kW
WARNING
When using electrical appliances, basic precautions should always be
taken to reduce the risk of fi re, electrical shock and injury, including
the following:
Read carefully these instructions before installation, operation of the
heater. Failure to adhere to the instructions could result in fi re, electric
shock, serious personal injury, and death or property damage. Review
frequently for continuing safe operation and instruction of future
users, if necessary.
IMPORTANT
INSTRUCTIONS
- Read all instructions before installing or using this heater.
- This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, like furniture,
pillows, bedding, papers, clothes, and curtains at least 36 in.
(915 mm) from the front of the heater and away from the sides and
rear.
- Extreme caution is necessary when any heater is used by or near
children or invalids and whenever the heater is left operating and
unattended.
- Do not operate any heater after it malfunctions. Disconnect pow er
at service panel and have heater inspected by a reputable electrician
before reusing.
- To disconnect heater, turn off power to heater circuit at main
disconnect panel.
- Do not use outdoors.
- Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electrical shock or fi re, or
damage the heater.
- To prevent a possible fi re, do not block air intakes or exhaust in any
way whatsoever.
- A heater has hot and arcing or sparking parts inside. Do not use it in
areas where gasoline, paint or fl ammable liquids are used or stored.
- Use this heater only as described in this manual. Any other use not
recommended by the manufacturer may cause fi re, electrical shock,
or injury.
- The thermostat should not be considered an infallible device in
cases where maintaining a temperature is considered critical. In
these particular cases, it is imperative to add a monitoring system to
avoid the consequences of a thermostat failure.
- This heater is not approved for use in corrosive atmospheres, wet
or very humid locations such as marine, green house or chemical
storage areas.
SAVE THESE INSTRUCTIONS
OPERATING
INSTRUCTIONS
The heater must be properly installed before it is used.
HEATER OPERATION
Start up
On a call for heat from either the remote thermostat or the unit
mounted thermostat the elements and fan will be energized.
When the thermostat is satisfi ed the elements will be deenergized.
The fan will continue to run until the residual heat is removed
from the heater. Then the fan will stop.
Automatic Reset Thermal High Limit
The heater has an automatic reset thermal high limit that will deener-
gize the heating elements if the interior temperatures of heater exceed
its setting. The limit will automatically reset when the heater interior
temperatures fall below its setting.
MAINTENANCE
INSTRUCTIONS
The heater motor is permanently lubricated.
Occasional cleaning of the inlet grille will prevent clogging.
Use a vacuum with a brush attachment.
Cleaning should be done while the heater is disconnected from
the main service panel. Wait until the housing and heating
elements cool before performing maintenance.
Any other servicing should be performed by a qualifi ed
technician.
WARRANTY
The manufacturer warrants the component parts of the heater
against defects in material and workmanship for a fi ve year
period following the date of purchase, under normal use and
service, when proof of purchase of such is provided to the
manufacturer. The obligation of the manufacturer, under the
terms of this warranty, will be to supply a new unit and this
releases the manufacturer from paying the installation costs
or other secondary charges linked to replacing the unit or the
component part(s).
INS263-201001-06
Reznor LLC
O’Fallon, MO USA 63368 - Tel.: 1 800 695-1901
www.ReznorHVAC.com
©2014 Reznor, LLC. All rights reserved. All other trademarks are the
property of their respective organizations.
INSTRUCTIONS